451 749

Cited 0 times in

Cited 1 times in

Accuracy and Feasibility of a Zero-Setup Implant Guide System Made of a Light-Cured Composite Resin with Simultaneous Flapless Sinus Augmentation: A Pilot Study

Authors
 Park, Jin Young  ;  Lee, Joo-Yeon  ;  Kim, Joo-Nyeon  ;  Paik, Jeong Won  ;  Lee, Jung Seok  ;  Jung, Ui Won  ;  Choi, Seong Ho  ;  CHA, Jae Kook 
Citation
 Applied Sciences-basel, Vol.11(17), 2021-09 
Article Number
 8085 
Journal Title
APPLIED SCIENCES-BASEL
ISSN
 2076-3417 
Issue Date
2021-09
Keywords
guided implant surgery ; sinus augmentation ; flapless surgery
Abstract
The aim of this study was to evaluate the accuracy and feasibility of flapless implant placement using a light-cured surgical template made of composite resin comprising dimethacrylate and diurethane, performed simultaneously with crestal sinus augmentation. This pilot study was a prospective, single-armed, controlled clinical trial. Four patients having an edentulous region in the posterior maxilla with 4 to 8 mm of residual ridge height were enrolled. Flapless fully-guided implant placement was performed using a zero-setup surgical template with simultaneous crestal sinus graft. Horizontal, vertical, and angular deviations of the placed implants from the planned positions were measured. Clinical observations were made, and implant stability was measured up to 3 months postoperatively. All four implants were placed and maintained successfully without complication. The mean deviations of the four implants were 1.27 and 1.85 mm horizontally at platform and apex, respectively, 0.84 mm vertically at apex, and 4.76 degrees in angle. Satisfactory implant stability was obtained in all implants at placement and 3 months. Fully-guided implant placement and crestal sinus graft using a zero-setup surgical template can be a safe and feasible method with acceptable accuracy. A randomized controlled trial should be performed in the future to validate its clinical performance in terms of surgical time, accuracy, and patient-reported outcomes.
DOI
10.3390/app11178085
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers
Yonsei Authors
Park, Jin Young(박진영) ORCID logo https://orcid.org/0000-0002-6408-1618
Paik, Jeong Won(백정원) ORCID logo https://orcid.org/0000-0002-5554-8503
Lee, Jung Seok(이중석) ORCID logo https://orcid.org/0000-0003-1276-5978
Jung, Ui Won(정의원) ORCID logo https://orcid.org/0000-0001-6371-4172
Cha, Jae Kook(차재국) ORCID logo https://orcid.org/0000-0001-6817-9834
Choi, Seong Ho(최성호) ORCID logo https://orcid.org/0000-0001-6704-6124
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/187306
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links