0 404

Cited 11 times in

Comparison of diagnostic performance of the ACR and Kwak TIRADS applying the ACR TIRADS' size thresholds for FNA

Authors
 Sun Huh  ;  Jung Hyun Yoon  ;  Hye Sun Lee  ;  Hee Jung Moon  ;  Vivian Youngjean Park  ;  Jin Young Kwak 
Citation
 EUROPEAN RADIOLOGY, Vol.31(7) : 5243-5250, 2021-07 
Journal Title
EUROPEAN RADIOLOGY
ISSN
 0938-7994 
Issue Date
2021-07
MeSH
Biopsy, Fine-Needle ; Humans ; ROC Curve ; Retrospective Studies ; Thyroid Neoplasms* ; Thyroid Nodule* ; Ultrasonography
Keywords
Biopsy, fine-needle ; Thyroid gland ; Thyroid neoplasm ; Thyroid nodule ; Ultrasonography
Abstract
Objective: To investigate the diagnostic performances and unnecessary fine-needle aspiration (FNA) rates of two point-scale based TIRADS and compare them with a modified version using the ACR TIRADS' size thresholds.

Methods: Our Institutional Review Board approved this retrospective study and waived the requirement for informed consent. A total of 2106 thyroid nodules 10 mm or larger in size in 2084 patients with definitive cytopathologic findings were included. Ultrasonography categories were assigned according to each guideline. We applied the ACR TIRADS' size thresholds for FNA to the Kwak TIRADS and defined it as the modified Kwak TIRADS (mKwak TIRADS). Diagnostic performances and unnecessary FNA rates were evaluated for both the original and modified guidelines.

Results: Of the original guidelines, the ACR TIRADS had higher specificity, accuracy, and area under the receiver operating characteristic curve (AUC) (63.1%, 68.9%, and 0.748, respectively). When the size threshold of the ACR TIRADS was applied to the Kwak TIRADS, the resultant mKwak TIRADS had higher specificity, accuracy, and AUC (64.7%, 70.3%, and 0.765, respectively) than the ACR TIRADS. The mKwak TIRADS also had a lower unnecessary FNA rate than the ACR TIRADS (54.8% and 56.4%, respectively). The false-negative rate of the Kwak TIRADS was the lowest (1.9%) among all TIRADS.

Conclusion: The modified Kwak TIRADS incorporating the size thresholds of the ACR TIRADS showed higher diagnostic performance and a lower unnecessary FNA rate than the original point-scale based TIRADS.

Key points: • Of the original guidelines, the ACR TIRADS had the highest specificity, accuracy, and area under the receiver operating characteristic curve (AUC) (63.1%, 68.9%, and 0.748, respectively). • When the size threshold of the ACR TIRADS was applied to the Kwak TIRADS, the resultant modified version of Kwak TIRADS had higher specificity, accuracy, and AUC (64.7%, 70.3%, and 0.765, respectively) than the ACR TIRADS. • The false-negative rate of the Kwak TIRADS was the lowest (1.9%) among all TIRADS.
Full Text
https://link.springer.com/article/10.1007/s00330-020-07591-1
DOI
10.1007/s00330-020-07591-1
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers
Yonsei Authors
Kwak, Jin Young(곽진영) ORCID logo https://orcid.org/0000-0002-6212-1495
Park, Vivian Youngjean(박영진) ORCID logo https://orcid.org/0000-0002-5135-4058
Yoon, Jung Hyun(윤정현) ORCID logo https://orcid.org/0000-0002-2100-3513
Lee, Hye Sun(이혜선) ORCID logo https://orcid.org/0000-0001-6328-6948
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/184511
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links