7 123

Cited 0 times in

Cited 0 times in

이중시기 다중검출기 전산화단층촬영에서 췌장의 감쇠치 변이: 조영제추적기법과 고정시간기법의 비교

Other Titles
 Variation of Attenuation Value of Pancreas at Dual Phase MDCT: Comparison of the Bolus-tracking Technique vs. the Fixed Scan Delay Protocol 
Authors
 유은혜  ;  김명진  ;  박승우  ;  이우정  ;  ·김기황 
Citation
 Journal of the Korean Radiological Society (대한영상의학회지), Vol.56(3) : 267-272, 2007-03 
Journal Title
Journal of the Korean Society of Radiology(대한영상의학회지)
ISSN
 1738-2637 
Issue Date
2007-03
Keywords
Pancreas ; Computed tomography (CT) ; helical ; Computed tomography (CT) ; contrast media
Abstract
PURPOSE: To clarify the difference between the bolus-tracking technique and a fixed scan delay protocol in the achievement of the optimal pancreatic phase of the pancreas with MDCT.
MATERIALS AND METHODS
526 patients underwent pancreatic and portal venous phase imaging of the pancreas using 16-channel MDCT. All the examinations were randomized into either scanning using a bolus-tracking technique with a scan delay of 20s after the aorta was enhanced > 100 HU (groups 1 and 2) or scanning with a scan delay of 38 s from the beginning of the injection (groups 3 and 4). A contrast material of 300 mgI/mL (groups 1 and 3) or 370 mgI/mL (groups 2 and 4) at an injection speed of 3 mL/sec was injected at 2 mL/kg body weight. The pancreatic CT attenuation values were compared.
RESULTS
The scan delay times of the pancreatic phase in groups 1 and 2 were 38+/-3.8s and 37.4+/-3.4s, respectively. At the pancreatic phase, the pancreatic attenuation values of groups 1 and 2 were slightly higher than those of groups 3 and 4 (115.5+/-15.4 vs 111.7+/-15.1HU; p=0.093, 128.3+/-17.1 vs 119+/-17.1HU; p=0.003). There was no significant difference between groups at the portal venous phase.
CONCLUSION
The use of a bolus-tracking technique in the optimal pancreatic phase of pancreatic CT does not significantly improve the pancreatic enhancement but does at higher iodine concentrations.
Files in This Item:
T992025619.pdf Download
DOI
10.3348/jkrs.2007.56.3.267
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Ki Whang(김기황)
Kim, Myeong Jin(김명진) ORCID logo https://orcid.org/0000-0001-7949-5402
Lee, Woo Jung(이우정) ORCID logo https://orcid.org/0000-0001-9273-261X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/206781
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links