Cited 0 times in
Cited 0 times in
이중시기 다중검출기 전산화단층촬영에서 췌장의 감쇠치 변이: 조영제추적기법과 고정시간기법의 비교
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이우정 | - |
dc.contributor.author | 김명진 | - |
dc.contributor.author | 김기황 | - |
dc.date.accessioned | 2025-07-25T06:28:29Z | - |
dc.date.available | 2025-07-25T06:28:29Z | - |
dc.date.issued | 2007-03 | - |
dc.identifier.issn | 1738-2637 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/206781 | - |
dc.description.abstract | PURPOSE: To clarify the difference between the bolus-tracking technique and a fixed scan delay protocol in the achievement of the optimal pancreatic phase of the pancreas with MDCT. MATERIALS AND METHODS 526 patients underwent pancreatic and portal venous phase imaging of the pancreas using 16-channel MDCT. All the examinations were randomized into either scanning using a bolus-tracking technique with a scan delay of 20s after the aorta was enhanced > 100 HU (groups 1 and 2) or scanning with a scan delay of 38 s from the beginning of the injection (groups 3 and 4). A contrast material of 300 mgI/mL (groups 1 and 3) or 370 mgI/mL (groups 2 and 4) at an injection speed of 3 mL/sec was injected at 2 mL/kg body weight. The pancreatic CT attenuation values were compared. RESULTS The scan delay times of the pancreatic phase in groups 1 and 2 were 38+/-3.8s and 37.4+/-3.4s, respectively. At the pancreatic phase, the pancreatic attenuation values of groups 1 and 2 were slightly higher than those of groups 3 and 4 (115.5+/-15.4 vs 111.7+/-15.1HU; p=0.093, 128.3+/-17.1 vs 119+/-17.1HU; p=0.003). There was no significant difference between groups at the portal venous phase. CONCLUSION The use of a bolus-tracking technique in the optimal pancreatic phase of pancreatic CT does not significantly improve the pancreatic enhancement but does at higher iodine concentrations. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한영상의학회 | - |
dc.relation.isPartOf | Journal of the Korean Society of Radiology(대한영상의학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | 이중시기 다중검출기 전산화단층촬영에서 췌장의 감쇠치 변이: 조영제추적기법과 고정시간기법의 비교 | - |
dc.title.alternative | Variation of Attenuation Value of Pancreas at Dual Phase MDCT: Comparison of the Bolus-tracking Technique vs. the Fixed Scan Delay Protocol | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Surgery (외과학교실) | - |
dc.contributor.googleauthor | 유은혜 | - |
dc.contributor.googleauthor | 김명진 | - |
dc.contributor.googleauthor | 박승우 | - |
dc.contributor.googleauthor | 이우정 | - |
dc.contributor.googleauthor | ·김기황 | - |
dc.identifier.doi | 10.3348/jkrs.2007.56.3.267 | - |
dc.contributor.localId | A02993 | - |
dc.contributor.localId | A00426 | - |
dc.contributor.localId | A00345 | - |
dc.relation.journalcode | J01843 | - |
dc.identifier.eissn | 2288-2928 | - |
dc.subject.keyword | Pancreas | - |
dc.subject.keyword | Computed tomography (CT) | - |
dc.subject.keyword | helical | - |
dc.subject.keyword | Computed tomography (CT) | - |
dc.subject.keyword | contrast media | - |
dc.contributor.alternativeName | Lee, Woo Jung | - |
dc.contributor.affiliatedAuthor | 이우정 | - |
dc.contributor.affiliatedAuthor | 김명진 | - |
dc.contributor.affiliatedAuthor | 김기황 | - |
dc.citation.volume | 56 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 267 | - |
dc.citation.endPage | 272 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Radiological Society (대한영상의학회지), Vol.56(3) : 267-272, 2007-03 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.