501 722

Cited 0 times in

Cited 1 times in

Application of point shearwave elastography to breast ultrasonography: Initial experience using “S-shearwave” in differential diagnosis

Other Titles
 Point Shearwave Elastography의 유방 초음파에서의 적용: “S-Shearwave”를 이용한 감별진단의 초기경험 
Authors
 Lee, M.H.  ;  Kim, E.-K.  ;  Lee, E.J.  ;  Kim, H.Y.  ;  Yoon, J.H. 
Citation
 Journal of the Korean Society of Radiology(대한영상의학회지), Vol.81(1) : 157-165, 2020-01 
Journal Title
Journal of the Korean Society of Radiology(대한영상의학회지)
ISSN
 1738-2637 
Issue Date
2020-01
Keywords
Breast ; Elasticity Imaging Techniques ; Neoplasm ; Ultrasonography
Abstract
Purpose To evaluate the optimal measurement location, cut-off value, and diagnostic performance of S-Shearwave in differential diagnosis of breast masses seen on ultrasonography (US). Materials and Methods During the study period, 225 breast masses in 197 women were included. S-Shearwave measurements were made by applying a square region-of-interest automatically generated by the US machine. Shearwave elasticity was measured three times at four different locations of the mass, and the highest shearwave elasticity was used for calculating the optimal cut-off value. Diagnostic performance was evaluated by using the area under the receiving operator characteristic curve (AUC). Results Of the 225 breast masses, 156 (69.3%) were benign and 69 (30.7%) were malignant. Mean S-Shearwave values were significantly higher for malignant masses (108.0 ± 70.0 kPa vs. 43.4 ± 38.3 kPa; p < 0.001). No significant differences were seen among AUC values at different measurement locations. With a cut-off value of 41.9 kPa, S-Shearwave showed 85.7% sensitivity, 63.9% specificity, 70.7% accuracy, and positive and negative predictive values of 51.7% and 90.8%, respectively. The AUCs for US and S-Shearwave did not show significant differences (p = 0.179). Conclusion S-Shearwave shows comparable diagnostic performance to that of grayscale US that can be applied for differential diagnosis of breast masses seen on US. Copyrights © 2020 The Korean Society of Radiology.
DOI
10.3348/jksr.2020.81.1.157
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Eun-Kyung(김은경) ORCID logo https://orcid.org/0000-0002-3368-5013
Yoon, Jung Hyun(윤정현) ORCID logo https://orcid.org/0000-0002-2100-3513
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/175320
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links