245 342

Cited 0 times in

Utility of Single Shot Fast Spin Echo Technique in Evaluating Pancreaticobiliary Diseases : T 2 - weighted Image and Magnetic Resonance Cholangiopancreatography

Other Titles
 췌담도질환의 평가에 있어서 단발고속스핀에코기법의 유용성 : T2강조영상과 자기공명췌담관조영술 
Authors
 Byoung Wook Choi  ;  Myeong Jin Kim  ;  Jae Bok Chung  ;  Heung Kyu Ko  ;  Dong Joon Kim  ;  Joo Hee Kim  ;  Jae Joon Chung  ;  Hyung Sik Yoo  ;  Jong Tae Lee 
Citation
 Journal of the Korean Radiologist Society (대한방사선의학회지), Vol.41(3) : 515-524, 1999 
Journal Title
Journal of the Korean Radiologist Society(대한방사선의학회지)
ISSN
 0301-2867 
Issue Date
1999
Keywords
Magnetic resonance(MR), half-Fourier imaging ; Bile ducts, MR ; Bile ducts, stenosis or obstruction ; Pancreatic ducts, MR ; Magnetic resonance (MR), rapid imaging
Abstract
PURPOSE: To evaluate the accuracy of T2-weighted imaging and MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. MATERIALS AND METHODS: B e t ween March and July 1997, axial and coronal T2-weighted images ( T E : 8 0 -2 00 msec) and MR cholangiopancreatograms(TE:800 -1 2 00 msec) were obtained in two ways [single slab (thickness:30 -50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male,48; female,26; age range, 3 0 -86 (mean,59)years] confirmed surgicopathologically(50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. RESULTS: Correct diagnosis was confirmed in 84 of 89 lesions (94 %). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respective l y. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERC P. Sensitivity and specificity for calculous disease were 96 % and 99.7 %, respective l y. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were rev i ewed retrospectively. CONCLUSION: The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreaticobiliary diseases.
Files in This Item:
T199903099.pdf Download
DOI
10.3348/jkrs.1999.41.3.515
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Ko, Heung Kyu(고흥규)
Kim, Myeong Jin(김명진) ORCID logo https://orcid.org/0000-0001-7949-5402
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/172893
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links