419 414

Cited 0 times in

혈관모형을 이용한 CT 혈관조영 영상의 질에 영향을 미치는 해부학적, 촬영 및 재구성 변수에 대한 연구

Other Titles
 Influence of Anatomical, Scanning, and Reconstructing Parameters on Image Quality of CT Angiography: Vascular Phantom Study 
Authors
 김양민  ;  정진욱  ;  김태훈  ;  김미영  ;  조준희  ;  차상훈 
Citation
 Journal of the Korean Radiologist Society (대한방사선의학회지), Vol.47(1) : 27-33, 2002 
Journal Title
Journal of the Korean Radiologist Society(대한방사선의학회지)
ISSN
 1738-2637 
Issue Date
2002
Abstract
Purpose: To investigate the image quality of CT angiograms obtained with various anatomical, scanning, and reconstruction parameters using a phantom with small vessels, and to determine the technique appropriate to a specific vascular anatomy. Materials and Methods: The vascular phantom consisted of three pairs of parallel tubes with a luminal size of 1, 2, and 3 mm. Using the phantom, CT scans were obtained at three inter-tubal distances (1, 2, and 3 mm), three angles of inclination relative to the z-axis (0 degree, 45 degree, and 90 degree), three collimation widths (1, 3, and 5 mm) and two pitch factors (1 and 2). Using axial images obtained at 1-, 2-, and 3-mm reconstruction intervals, two types of three-dimensional images were rendered, and the quality of 972 such images was subjectively graded in terms of edge definition and artifact by three radiologists. Results: All vessels parallel to the z-axis showed good image quality irrespective of other factors. A pair of vessels separated by 1 mm appeared to be stuck to each other. As collimation width and reconstruction interval increased, image quality decreased significantly and artifact increased. The quality of images obtained at 3 mm collimation and with a 6 mm increment was significantly better where collimation and increment were both 5 mm (p=0.001). Vessels 1 mm in size suffered artifactual degradation, especially in the case of SSD images. Most obliquely oriented vessels showed stair-step artifact, which tended to be severe when the reconstruction interval was large. Conclusion: In small vessels perpendicular to or inclined relative to the z-axis, a smaller collimation width and reconstruction interval lessens image degradation. When wider scan coverage is intended, a larger pitch rather than a larger collimation width is recommended. To lessen the artifacts occurring where vessels are obliquely oriented, the reconstruction interval should be reduced.
Files in This Item:
T200210666.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Tae Hoon(김태훈) ORCID logo https://orcid.org/0000-0003-3598-2529
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/144538
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links