혈관모형을 이용한 CT 혈관조영 영상의 질에 영향을 미치는 해부학적, 촬영 및 재구성 변수에 대한 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김태훈 | - |
dc.date.accessioned | 2016-05-16T11:25:58Z | - |
dc.date.available | 2016-05-16T11:25:58Z | - |
dc.date.issued | 2002 | - |
dc.identifier.issn | 1738-2637 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/144538 | - |
dc.description.abstract | Purpose: To investigate the image quality of CT angiograms obtained with various anatomical, scanning, and reconstruction parameters using a phantom with small vessels, and to determine the technique appropriate to a specific vascular anatomy. Materials and Methods: The vascular phantom consisted of three pairs of parallel tubes with a luminal size of 1, 2, and 3 mm. Using the phantom, CT scans were obtained at three inter-tubal distances (1, 2, and 3 mm), three angles of inclination relative to the z-axis (0 degree, 45 degree, and 90 degree), three collimation widths (1, 3, and 5 mm) and two pitch factors (1 and 2). Using axial images obtained at 1-, 2-, and 3-mm reconstruction intervals, two types of three-dimensional images were rendered, and the quality of 972 such images was subjectively graded in terms of edge definition and artifact by three radiologists. Results: All vessels parallel to the z-axis showed good image quality irrespective of other factors. A pair of vessels separated by 1 mm appeared to be stuck to each other. As collimation width and reconstruction interval increased, image quality decreased significantly and artifact increased. The quality of images obtained at 3 mm collimation and with a 6 mm increment was significantly better where collimation and increment were both 5 mm (p=0.001). Vessels 1 mm in size suffered artifactual degradation, especially in the case of SSD images. Most obliquely oriented vessels showed stair-step artifact, which tended to be severe when the reconstruction interval was large. Conclusion: In small vessels perpendicular to or inclined relative to the z-axis, a smaller collimation width and reconstruction interval lessens image degradation. When wider scan coverage is intended, a larger pitch rather than a larger collimation width is recommended. To lessen the artifacts occurring where vessels are obliquely oriented, the reconstruction interval should be reduced. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 27~33 | - |
dc.relation.isPartOf | Journal of the Korean Radiologist Society (대한방사선의학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 혈관모형을 이용한 CT 혈관조영 영상의 질에 영향을 미치는 해부학적, 촬영 및 재구성 변수에 대한 연구 | - |
dc.title.alternative | Influence of Anatomical, Scanning, and Reconstructing Parameters on Image Quality of CT Angiography: Vascular Phantom Study | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학) | - |
dc.contributor.googleauthor | 김양민 | - |
dc.contributor.googleauthor | 정진욱 | - |
dc.contributor.googleauthor | 김태훈 | - |
dc.contributor.googleauthor | 김미영 | - |
dc.contributor.googleauthor | 조준희 | - |
dc.contributor.googleauthor | 차상훈 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A01086 | - |
dc.relation.journalcode | J01844 | - |
dc.contributor.alternativeName | Kim, Tae Hoon | - |
dc.contributor.affiliatedAuthor | Kim, Tae Hoon | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 47 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 27 | - |
dc.citation.endPage | 33 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Radiologist Society (대한방사선의학회지), Vol.47(1) : 27-33, 2002 | - |
dc.identifier.rimsid | 50324 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.