338 522

Cited 0 times in

Dosimetric Evaluation of the Mean Glandular Dose for Mammography in Korean Women: A Preliminary Report

Authors
 Ki Keun Oh  ;  Jin Hur  ;  Sung Sil Choo  ;  Eun Kyung Kim 
Citation
 YONSEI MEDICAL JOURNAL, Vol.44(5) : 863-868, 2003 
Journal Title
YONSEI MEDICAL JOURNAL
ISSN
 0513-5796 
Issue Date
2003
MeSH
Adult ; Breast/anatomy & histology ; Female ; Humans ; Mammography* ; Middle Aged ; Radiation Dosage*
Keywords
radiation ; mammography ; dosimetry ; phantom
Abstract
The purpose of this study was to evaluate the thickness of the compressed breast in mediolateral oblique (MLO) and craniocaudal (CC) mammograms, to relate these thickness and breast patterns to mean glandular dose (MGD) in Korean women, and to evaluate the suitability of using the American College of Radiology's Recommendations for Korean women from a quality assurance standpoint. The study population consisted of 92 paired MLO and CC mammograms obtained on one mammographic unit. The digital readouts of compressed breast thickness, applied compression force and tube voltage were recorded. Entrance skin exposure was measured by dosimetry. MGD was calculated by multiplying entrance skin exposure by the exposure-to-absorbed dose conversion factor. The range of breast thickness was 1.3 - 6.2 cm in CC mammograms with a mean breast thickness of 3.6 cm, and 1.6 - 6.5 cm in MLO mammograms with a mean breast thickness of 3.9 cm. MGDs in CC and MLO mammograms were 1.77 mSv and 1.88 mSv per view, respectively. Breast composition patterns were divided into 4 groups according to ACR BI-RADS; P1 (n=20), P2 (n=16), P3 (n=48) and P4 (n=8).

The MGDs for these groups were: 1.82, 1.84, 1.84, and 1.91 mSv, respectively. When subjects were subdivided by breast thickness into three groups, namely, below 3 cm, 3 cm to 4.2 cm, aaa and above 4.2 cm, the corresponding MGDs were 1.83, 1.86, and 1.91 mSv.

According to our initial trial, the mean breast thickness and the MGDs of Korean women are lower than recommended by the American College of Radiology, which are commonly used for quality assurance purposes.
Files in This Item:
T200305476.pdf Download
DOI
10.3349/ymj.2003.44.5.863
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Eun-Kyung(김은경) ORCID logo https://orcid.org/0000-0002-3368-5013
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/114113
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links