3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성

DC Field Value Language
dc.contributor.author허경석-
dc.contributor.author김기덕-
dc.contributor.author김종관-
dc.contributor.author박창서-
dc.contributor.author박혁-
dc.contributor.author정호걸-
dc.contributor.author최성호-
dc.date.accessioned2015-06-10T12:16:22Z-
dc.date.available2015-06-10T12:16:22Z-
dc.date.issued2006-
dc.identifier.issn1229-8212-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/109498-
dc.description.abstractPurpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.-
dc.description.statementOfResponsibilityopen-
dc.format.extent89~94-
dc.languageKorean-
dc.publisher대한구강악안면방사선학회-
dc.relation.isPartOfKorean Journal of Oral and Maxillofacial Radiology (대한구강악안면방사선학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성-
dc.title.alternativeClinical usefulness of facial soft tissues thickness measurement using3D computed tomographic images-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Periodontology (치주과학)-
dc.contributor.googleauthor정호걸-
dc.contributor.googleauthor김기덕-
dc.contributor.googleauthor한승호-
dc.contributor.googleauthor허경석-
dc.contributor.googleauthor이제범-
dc.contributor.googleauthor박혁-
dc.contributor.googleauthor최성호-
dc.contributor.googleauthor김종관-
dc.contributor.googleauthor박창서-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA04342-
dc.contributor.localIdA00332-
dc.contributor.localIdA01715-
dc.contributor.localIdA01733-
dc.contributor.localIdA03784-
dc.contributor.localIdA04081-
dc.contributor.localIdA00914-
dc.relation.journalcodeJ02085-
dc.subject.keywordFacial Soft Tissue Thickness-
dc.subject.keywordMeasurement-
dc.subject.keywordImaging-
dc.subject.keywordThree-Dimensional-
dc.subject.keywordTomography-
dc.subject.keywordX-ray computed-
dc.subject.keywordSlice Thickness-
dc.contributor.alternativeNameHu, Kyung Seok-
dc.contributor.alternativeNameKim, Kee Deog-
dc.contributor.alternativeNameKim, Chong Kwan-
dc.contributor.alternativeNamePark, Chang Seo-
dc.contributor.alternativeNamePark, Hyuk-
dc.contributor.alternativeNameJeong, Ho Gul-
dc.contributor.alternativeNameChoi, Seong Ho-
dc.contributor.affiliatedAuthorHu, Kyung Seok-
dc.contributor.affiliatedAuthorKim, Kee Deog-
dc.contributor.affiliatedAuthorPark, Chang Seo-
dc.contributor.affiliatedAuthorPark, Hyuk-
dc.contributor.affiliatedAuthorJeong, Ho Gul-
dc.contributor.affiliatedAuthorChoi, Seong Ho-
dc.contributor.affiliatedAuthorKim, Chong Kwan-
dc.rights.accessRightsfree-
dc.citation.volume36-
dc.citation.number2-
dc.citation.startPage89-
dc.citation.endPage94-
dc.identifier.bibliographicCitationKorean Journal of Oral and Maxillofacial Radiology, Vol.36(2) : 89-94, 2006-
dc.identifier.rimsid44874-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Advanced General Dentistry (통합치의학과) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Oral Biology (구강생물학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Oral and Maxillofacial Radiology (영상치의학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.