Cited 23 times in
Real-Time Elastography in the Evaluation of Diffuse Thyroid Disease: A Study Based on Elastography Histogram Parameters
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 곽진영 | - |
dc.contributor.author | 김은경 | - |
dc.contributor.author | 문희정 | - |
dc.contributor.author | 윤정현 | - |
dc.contributor.author | 이혜선 | - |
dc.date.accessioned | 2015-01-06T17:07:50Z | - |
dc.date.available | 2015-01-06T17:07:50Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 0301-5629 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/99396 | - |
dc.description.abstract | The purpose of this study was to evaluate the diagnostic performance of quantitative histogram parameters using real-time tissue elastography (RTE) in the diagnosis of patients with diffuse thyroid disease. One hundred and sixteen patients (mean age, 43.7 ± 10.97 y) who had undergone pre-operative staging ultrasonography and RTE were included. For each patient, 11 parameters were obtained from RTE images, from which the “elastic index” was calculated. Diagnostic performance of the elastic index and that of the 11 parameters on RTE were calculated and compared. Of the 116 patients, 31 had diffuse thyroid disease and 85 had normal thyroid parenchyma. Area under the receiver operating characteristic curve (Az) of MEAN (average relative value) elasticity was high (0.737), without significant differences from other elasticity values. Diagnostic performance of the elastic index was higher than the MEAN, Az = 0.753, without significance (p = 0.802). In conclusion, RTE using the elastic index was found to have good diagnostic performance and may be useful in the diagnosis and management of patients with diffuse thyroid disease. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 2012~2019 | - |
dc.relation.isPartOf | ULTRASOUND IN MEDICINE AND BIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Computer Systems | - |
dc.subject.MESH | Elasticity Imaging Techniques/methods* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Principal Component Analysis | - |
dc.subject.MESH | ROC Curve | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Thyroid Diseases/diagnostic imaging* | - |
dc.subject.MESH | Thyroid Gland/diagnostic imaging* | - |
dc.subject.MESH | Young Adult | - |
dc.title | Real-Time Elastography in the Evaluation of Diffuse Thyroid Disease: A Study Based on Elastography Histogram Parameters | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학) | - |
dc.contributor.googleauthor | Jung Hyun Yoon | - |
dc.contributor.googleauthor | Jaeheung Yoo | - |
dc.contributor.googleauthor | Eun-Kyung Kim | - |
dc.contributor.googleauthor | Hee Jung Moon | - |
dc.contributor.googleauthor | Hye Sun Lee | - |
dc.contributor.googleauthor | Jae Young Seo | - |
dc.contributor.googleauthor | Hye Young Park | - |
dc.contributor.googleauthor | Woon-Ju Park | - |
dc.contributor.googleauthor | Jin Young Kwak | - |
dc.identifier.doi | 10.1016/j.ultrasmedbio.2014.03.033 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A03312 | - |
dc.contributor.localId | A00182 | - |
dc.contributor.localId | A00801 | - |
dc.contributor.localId | A01397 | - |
dc.contributor.localId | A02595 | - |
dc.relation.journalcode | J02769 | - |
dc.identifier.eissn | 1879-291X | - |
dc.identifier.pmid | 24973828 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0301562914002191 | - |
dc.subject.keyword | Diffuse thyroid disease | - |
dc.subject.keyword | Real-time elastography | - |
dc.subject.keyword | Thyroid | - |
dc.subject.keyword | Thyroiditis | - |
dc.subject.keyword | Ultrasound | - |
dc.contributor.alternativeName | Kwak, Jin Young | - |
dc.contributor.alternativeName | Kim, Eun Kyung | - |
dc.contributor.alternativeName | Moon, Heui Jeong | - |
dc.contributor.alternativeName | Yoon, Jung Hyun | - |
dc.contributor.alternativeName | Lee, Hye Sun | - |
dc.contributor.affiliatedAuthor | Lee, Hye Sun | - |
dc.contributor.affiliatedAuthor | Kwak, Jin Young | - |
dc.contributor.affiliatedAuthor | Kim, Eun-Kyung | - |
dc.contributor.affiliatedAuthor | Moon, Heui Jeong | - |
dc.contributor.affiliatedAuthor | Yoon, Jung Hyun | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 40 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 2012 | - |
dc.citation.endPage | 2019 | - |
dc.identifier.bibliographicCitation | ULTRASOUND IN MEDICINE AND BIOLOGY, Vol.40(9) : 2012-2019, 2014 | - |
dc.identifier.rimsid | 57239 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.