289 588

Cited 5 times in

Prospective Evaluation of the Accuracy of MDCT Angiography for Living Kidney Donor

Authors
 Myung Up Kim  ;  Kyung Hwa Choi  ;  Seung Choul Yang  ;  Young Taik Oh  ;  Woong Kyu Han 
Citation
 KOREAN JOURNAL OF UROLOGY, Vol.52(2) : 124-129, 2011 
Journal Title
KOREAN JOURNAL OF UROLOGY
ISSN
 2005-6737 
Issue Date
2011
Keywords
Kidney transplantation ; Living donors ; Renal artery ; Renal veins ; Spiral computed tomography
Abstract
PURPOSE: In donor nephrectomy, it is important to understand the exact anatomy of the blood vessels during minimally invasive surgery. We prospectively analyzed the accuracy of the vessel structures obtained by use of 64-row multi-detector computed tomography (MDCT) angiography compared with the actual vessel structure observed during surgery. MATERIALS AND METHODS: We analyzed 238 patients who underwent donor nephrectomy from July 2007 to August 2010. Before the operation, MDCT angiography was performed, and after the operation, the surgeons themselves wrote the protocol. The ipsilateral artery, the number of veins, the association with the run of the hilar vessel, and other vascular anomalies in computed tomography (CT) angiography and in the donor protocol were summarized. RESULTS: Among 238 patients, nephrectomy was performed on the left side in 199 patients. The accuracy of MDCT for the artery and the vein was 93.3% and 92.4%, respectively. Accuracy did not differ significantly on the left and right sides (artery: p=0.124; vein: p=0.174). In 199 patients, the CT findings for the lumbar vein were compared with the surgical findings. The overall accuracy was shown to be 84.9%, and the accuracy of the group drained to the inferior vena cava (54%) was significantly different (p<0.01) from that of the group drained to the renal vein (98.6%). Thus, it may be necessary to pay close attention to the interpretation of the findings for the lumbar vein. CONCLUSIONS: MDCT angiography is important for understanding the exact anatomy of blood vessels before minimally invasive surgery. We showed that 64-channel MDCT has high accuracy in the main vessel and hilar vessels. However, close attention to the interpretation of the CT findings for the lumbar vein may be required.
Files in This Item:
T201101049.pdf Download
DOI
10.4111/kju.2011.52.2.124
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Urology (비뇨의학교실) > 1. Journal Papers
Yonsei Authors
Yang, Seung Choul(양승철)
Oh, Young Taik(오영택) ORCID logo https://orcid.org/0000-0002-4438-8890
Choi, Kyung Hwa(최경화)
Han, Woong Kyu(한웅규) ORCID logo https://orcid.org/0000-0002-2527-4046
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/92955
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links