Cited 47 times in
Interobserver variability and diagnostic performance in US assessment of thyroid nodule according to size
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 곽진영 | - |
dc.contributor.author | 김은경 | - |
dc.contributor.author | 문희정 | - |
dc.contributor.author | 박소희 | - |
dc.contributor.author | 박숙진 | - |
dc.contributor.author | 손은주 | - |
dc.contributor.author | 이혜선 | - |
dc.date.accessioned | 2014-12-19T17:45:13Z | - |
dc.date.available | 2014-12-19T17:45:13Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 0172-4614 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/91991 | - |
dc.description.abstract | PURPOSE: To evaluate the interobserver variability for US assessments of thyroid nodules and analyze the diagnostic performances of US assessments in thyroid nodules according to nodule size. MATERIALS AND METHODS: This was an IRB-approved retrospective study with waiver of informed consent. A total of 400 surgically-confirmed thyroid nodules were included. Nodules were divided into 4 groups by size; group 1 (nodule size < 5 mm), group 2 (5 mm ≤ nodule size < 10 mm), group 3 (10 mm ≤ nodule size < 20 mm), and group 4 (nodule size ≥ 20 mm). Three experienced (7 - 10 years) radiologists retrospectively reviewed the US images. Agreement of each US descriptor and final US assessment, and diagnostic performances were calculated in each group and compared. RESULTS: Composition represented substantial or good agreement (k = 0.719 - 0.89). Margin showed the lowest agreement (k = 0.322 - 0.365). Individual kappa values for final assessment according to nodule size were as follows: group 1 (k = 0.674), group 2 (k = 0.596), group 3 (k = 0.674), and group 4 (k = 0.673). Specificity, PPV, and accuracy were significantly different among the groups with different size (p value < 0.05) and lowest in group 1. NPV, specificity, PPV and accuracy except PPV of observer 3 increased with nodule size (p < 0.05). CONCLUSION: Interobserver agreements were relatively good (k = 0.637) in final US assessment regardless of nodule size in experienced radiologists. High false-positive rate was observed in US assessment in nodules less than 5 mm in maximum diameter. | - |
dc.description.statementOfResponsibility | open | - |
dc.relation.isPartOf | ULTRASCHALL IN DER MEDIZIN | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adolescent | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Biopsy, Fine-Needle | - |
dc.subject.MESH | Diagnosis, Differential | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Observer Variation | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Thyroid Gland/diagnostic imaging | - |
dc.subject.MESH | Thyroid Gland/pathology | - |
dc.subject.MESH | Thyroid Gland/surgery | - |
dc.subject.MESH | Thyroid Neoplasms/diagnostic imaging* | - |
dc.subject.MESH | Thyroid Neoplasms/pathology | - |
dc.subject.MESH | Thyroid Neoplasms/surgery | - |
dc.subject.MESH | Thyroid Nodule/diagnostic imaging* | - |
dc.subject.MESH | Thyroid Nodule/pathology | - |
dc.subject.MESH | Thyroid Nodule/surgery | - |
dc.subject.MESH | Tumor Burden | - |
dc.subject.MESH | Ultrasonography, Interventional | - |
dc.subject.MESH | Young Adult | - |
dc.title | Interobserver variability and diagnostic performance in US assessment of thyroid nodule according to size | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Yonsei Biomedical Research Center (연세의생명연구원) | - |
dc.contributor.googleauthor | S. J. Park | - |
dc.contributor.googleauthor | S. H. Park | - |
dc.contributor.googleauthor | Y. J. Choi | - |
dc.contributor.googleauthor | D. W. Kim | - |
dc.contributor.googleauthor | E. J. Son | - |
dc.contributor.googleauthor | H. S. Lee | - |
dc.contributor.googleauthor | J. H. Yoon | - |
dc.contributor.googleauthor | E.-K. Kim | - |
dc.contributor.googleauthor | H. J. Moon | - |
dc.contributor.googleauthor | J. Y. Kwak | - |
dc.identifier.doi | 10.1055/s-0032-1325404 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A03312 | - |
dc.contributor.localId | A01530 | - |
dc.contributor.localId | A00182 | - |
dc.contributor.localId | A00801 | - |
dc.contributor.localId | A01397 | - |
dc.contributor.localId | A01544 | - |
dc.contributor.localId | A01988 | - |
dc.relation.journalcode | J02766 | - |
dc.identifier.eissn | 1438-8782 | - |
dc.identifier.pmid | 23108925 | - |
dc.identifier.url | https://www.thieme-connect.com/DOI/DOI?10.1055/s-0032-1325404 | - |
dc.subject.keyword | head/neck | - |
dc.subject.keyword | tumor | - |
dc.subject.keyword | ultrasound | - |
dc.contributor.alternativeName | Kwak, Jin Young | - |
dc.contributor.alternativeName | Kim, Eun Kyung | - |
dc.contributor.alternativeName | Moon, Heui Jeong | - |
dc.contributor.alternativeName | Park, So Hee | - |
dc.contributor.alternativeName | Park, Suk Jin | - |
dc.contributor.alternativeName | Son, Eun Ju | - |
dc.contributor.alternativeName | Lee, Hye Sun | - |
dc.contributor.affiliatedAuthor | Lee, Hye Sun | - |
dc.contributor.affiliatedAuthor | Park, So Hee | - |
dc.contributor.affiliatedAuthor | Kwak, Jin Young | - |
dc.contributor.affiliatedAuthor | Kim, Eun-Kyung | - |
dc.contributor.affiliatedAuthor | Moon, Heui Jeong | - |
dc.contributor.affiliatedAuthor | Park, Suk Jin | - |
dc.contributor.affiliatedAuthor | Son, Eun Ju | - |
dc.citation.volume | 33 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 186 | - |
dc.citation.endPage | 190 | - |
dc.identifier.bibliographicCitation | ULTRASCHALL IN DER MEDIZIN, Vol.33(7) : 186-190, 2012 | - |
dc.identifier.rimsid | 30053 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.