3 668

Cited 0 times in

Interobserver variability and diagnostic performance in US assessment of thyroid nodule according to size

DC Field Value Language
dc.contributor.author곽진영-
dc.contributor.author김은경-
dc.contributor.author문희정-
dc.contributor.author박소희-
dc.contributor.author박숙진-
dc.contributor.author손은주-
dc.contributor.author이혜선-
dc.date.accessioned2014-12-19T17:45:13Z-
dc.date.available2014-12-19T17:45:13Z-
dc.date.issued2012-
dc.identifier.issn0172-4614-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/91991-
dc.description.abstractPURPOSE: To evaluate the interobserver variability for US assessments of thyroid nodules and analyze the diagnostic performances of US assessments in thyroid nodules according to nodule size. MATERIALS AND METHODS: This was an IRB-approved retrospective study with waiver of informed consent. A total of 400 surgically-confirmed thyroid nodules were included. Nodules were divided into 4 groups by size; group 1 (nodule size < 5 mm), group 2 (5 mm ≤ nodule size < 10 mm), group 3 (10 mm ≤ nodule size < 20 mm), and group 4 (nodule size ≥ 20 mm). Three experienced (7 - 10 years) radiologists retrospectively reviewed the US images. Agreement of each US descriptor and final US assessment, and diagnostic performances were calculated in each group and compared. RESULTS: Composition represented substantial or good agreement (k = 0.719 - 0.89). Margin showed the lowest agreement (k = 0.322 - 0.365). Individual kappa values for final assessment according to nodule size were as follows: group 1 (k = 0.674), group 2 (k = 0.596), group 3 (k = 0.674), and group 4 (k = 0.673). Specificity, PPV, and accuracy were significantly different among the groups with different size (p value < 0.05) and lowest in group 1. NPV, specificity, PPV and accuracy except PPV of observer 3 increased with nodule size (p < 0.05). CONCLUSION: Interobserver agreements were relatively good (k = 0.637) in final US assessment regardless of nodule size in experienced radiologists. High false-positive rate was observed in US assessment in nodules less than 5 mm in maximum diameter.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfULTRASCHALL IN DER MEDIZIN-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHBiopsy, Fine-Needle-
dc.subject.MESHDiagnosis, Differential-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHObserver Variation-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHThyroid Gland/diagnostic imaging-
dc.subject.MESHThyroid Gland/pathology-
dc.subject.MESHThyroid Gland/surgery-
dc.subject.MESHThyroid Neoplasms/diagnostic imaging*-
dc.subject.MESHThyroid Neoplasms/pathology-
dc.subject.MESHThyroid Neoplasms/surgery-
dc.subject.MESHThyroid Nodule/diagnostic imaging*-
dc.subject.MESHThyroid Nodule/pathology-
dc.subject.MESHThyroid Nodule/surgery-
dc.subject.MESHTumor Burden-
dc.subject.MESHUltrasonography, Interventional-
dc.subject.MESHYoung Adult-
dc.titleInterobserver variability and diagnostic performance in US assessment of thyroid nodule according to size-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentYonsei Biomedical Research Center (연세의생명연구원)-
dc.contributor.googleauthorS. J. Park-
dc.contributor.googleauthorS. H. Park-
dc.contributor.googleauthorY. J. Choi-
dc.contributor.googleauthorD. W. Kim-
dc.contributor.googleauthorE. J. Son-
dc.contributor.googleauthorH. S. Lee-
dc.contributor.googleauthorJ. H. Yoon-
dc.contributor.googleauthorE.-K. Kim-
dc.contributor.googleauthorH. J. Moon-
dc.contributor.googleauthorJ. Y. Kwak-
dc.identifier.doi23108925-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03312-
dc.contributor.localIdA01530-
dc.contributor.localIdA00182-
dc.contributor.localIdA00801-
dc.contributor.localIdA01397-
dc.contributor.localIdA01544-
dc.contributor.localIdA01988-
dc.relation.journalcodeJ02766-
dc.identifier.eissn1438-8782-
dc.identifier.pmid23108925-
dc.identifier.urlhttps://www.thieme-connect.com/DOI/DOI?10.1055/s-0032-1325404-
dc.subject.keywordhead/neck-
dc.subject.keywordtumor-
dc.subject.keywordultrasound-
dc.contributor.alternativeNameKwak, Jin Young-
dc.contributor.alternativeNameKim, Eun Kyung-
dc.contributor.alternativeNameMoon, Heui Jeong-
dc.contributor.alternativeNamePark, So Hee-
dc.contributor.alternativeNamePark, Suk Jin-
dc.contributor.alternativeNameSon, Eun Ju-
dc.contributor.alternativeNameLee, Hye Sun-
dc.contributor.affiliatedAuthorLee, Hye Sun-
dc.contributor.affiliatedAuthorPark, So Hee-
dc.contributor.affiliatedAuthorKwak, Jin Young-
dc.contributor.affiliatedAuthorKim, Eun-Kyung-
dc.contributor.affiliatedAuthorMoon, Heui Jeong-
dc.contributor.affiliatedAuthorPark, Suk Jin-
dc.contributor.affiliatedAuthorSon, Eun Ju-
dc.citation.volume33-
dc.citation.number7-
dc.citation.startPage186-
dc.citation.endPage190-
dc.identifier.bibliographicCitationULTRASCHALL IN DER MEDIZIN, Vol.33(7) : 186-190, 2012-
dc.identifier.rimsid30053-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.