3 626

Cited 0 times in

Thrombus imaging in acute ischaemic stroke using thin-slice unenhanced CT: comparison of conventional sequential CT and helical CT.

Authors
 Sung Soo Ahn  ;  Eung Yeop Kim 
Citation
 EUROPEAN RADIOLOGY, Vol.22(11) : 2392-2396, 2012 
Journal Title
EUROPEAN RADIOLOGY
ISSN
 0938-7994 
Issue Date
2012
MeSH
Aged ; Carotid Artery, Internal/pathology ; Diagnostic Imaging/methods ; Female ; Humans ; Image Processing, Computer-Assisted ; Ischemia/pathology* ; Male ; Middle Aged ; Middle Cerebral Artery/pathology ; Reproducibility of Results ; Stroke/diagnosis* ; Stroke/pathology ; Thrombosis/pathology* ; Tomography, Spiral Computed/methods* ; Tomography, X-Ray Computed/methods*
Keywords
Multidetector CT ; Thrombus ; Brain infarction ; Thrombolysis ; Stroke
Abstract
OBJECTIVES: Thin-slice helical unenhanced CT can be used for thrombus imaging but increases radiation exposure. Conventional sequential images obtained by multidetector CT can be reconstructed into thin-slice images. The purpose of this study was to evaluate if conventional sequential unenhanced CT images can replace helical unenhanced CT for thrombus imaging.

METHODS: Fifty consecutive patients with acute ischaemic stroke underwent both 5-mm conventional sequential unenhanced CT and helical unenhanced CT. Each of the sequential and helical unenhanced CT images was subsequently reconstructed into four 1.25-mm images. Thrombus volumes and HU were measured semi-automatically using both types of unenhanced CT. Thrombus HU ratio (rHU) was calculated using the HU of the contralateral segment. The intraclass correlation coefficient (ICC) and Bland-Altman plots were used to assess measurement agreement.

RESULTS: The mean rHUs were 1.47 ± 0.17 for sequential unenhanced CT and 1.47 ± 0.18 helical unenhanced CT (P = 0.542). The mean thrombus volumes were 124.25 ± 125.65 mm(3) and 117.84 ± 124.32 mm(3) on sequential and helical unenhanced CT images, respectively (P = 0.063). Measurement agreement between thrombus volumes from the two unenhanced CT images was high (ICC = 0.981).

CONCLUSIONS: Thin-slice unenhanced CT images reconstructed from 5-mm sequential images can replace helical unenhanced CT for thrombus imaging in acute ischaemic stroke. KEY POINTS : • Unenhanced CT is used to evaluate intra-arterial thrombus. • Thrombus HU and volume measurements using sequential or helical CT are comparable. • Conventional sequential images can replace helical CT for thrombus imaging. • Radiation dose for thrombus imaging can be reduced using sequential CT.
Full Text
http://link.springer.com/article/10.1007%2Fs00330-012-2518-y
DOI
22653288
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Eung Yeop(김응엽)
Ahn, Sung Soo(안성수) ORCID logo https://orcid.org/0000-0002-0503-5558
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/90255
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links