649 844

Cited 0 times in

초극소저체중 출생아에서 발생한 태변 연관 장폐색증

Other Titles
 Meconium-related Ileus in Extremely Low-birth Weight Newborn Infants Meconium-related Ileus in ELBWI 
Authors
 유하양  ;  신정은  ;  은호선  ;  이순민  ;  박민수  ;  이미정  ;  김명준  ;  남궁란  ;  이철  ;  박국인 
Citation
 Neonatal Medicine, Vol.20(1) : 121-128, 2013 
Journal Title
Neonatal Medicine
ISSN
 2287-9412 
Issue Date
2013
Keywords
Meconium-related ileus ; Extremely low-birth weight newborn infants ; Hyperosmolar water-soluble contrast enema
Abstract
Purpose
Meconium-related ileus (MRI) is one of the major causes of bowel obstruction in extremely low-birth weight newborn infants (ELBWI). Hyperosmolar water-soluble contrast (HWSC) enemas been recognized to be an effective treatment for MRI. The purpose of this study is to observe clinical findings of MRI accompanied by ELBWI and evaluate the therapeutic efficacy and complications of HWSC enemas.

Methods
A total of 15 ELBWI with MRI were treated with HWSC enemas under the guidance of ultrasonography at the bedside in the NICU between 2008 and 2011. Clinical findings of 15 patients were reviewed and compared with those of 48 ELBWI without MRI administered to NICU during the same period. Radiological findings, therapeutic efficacy and complications of HWSC enemas in patients with MRI were also reviewed.

Results
Patients with MRI, compared to those without MRI, showed the following significantly lower Apgar score at 1 minute, higher incidence of preeclampsia, bronchopulmonary dysplasia and sepsis, and longer duration of the first meconium passing and non-feeding per oral. Fourteen patients with MRI had resolved bowel obstruction successfully following 1-2 trials of enema. One case was not relieved following 3 trials of enema, showed no clinical improvement, and died of severe intraventricular hemorrhage and multi-organ failure at 45 days old. No complications associated with HWSC enemas were observed in all cases.

Conclusion
Administration of HWSC enemas under the guidance of abdomen ultrasonography in the NICU is safe and efficacious for the rapid diagnosis and treatment of MRI even accompanied by ELBWI.
Files in This Item:
T201303450.pdf Download
DOI
10.5385/nm.2013.20.1.121
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Pediatrics (소아과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Myung Joon(김명준) ORCID logo https://orcid.org/0000-0002-4608-0275
Namgung, Ran(남궁란) ORCID logo https://orcid.org/0000-0001-7182-9535
Park, Kook In(박국인) ORCID logo https://orcid.org/0000-0001-8499-9293
Park, Min Soo(박민수) ORCID logo https://orcid.org/0000-0002-4395-9938
Yu, Ha Yang(유하양)
Eun, Ho Seon(은호선) ORCID logo https://orcid.org/0000-0001-7212-0341
Lee, Mi-Jung(이미정) ORCID logo https://orcid.org/0000-0003-3244-9171
Lee, Soon Min(이순민) ORCID logo https://orcid.org/0000-0003-0174-1065
Lee, Chul(이철)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/88088
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links