dc.description.abstractINTRODUCTION: Several methods are available to enhance the precision of miniscrew placement. The use of surgical guides based on cone-beam computed tomography is indicated especially in patients with risky or difficult anatomic situations. The purpose of this study was to evaluate the accuracy of miniscrew placement by using surgical guides developed with computer-aided design and manufacturing techniques. METHODS: Miniscrews were placed in cadaver maxillae using stereolithographic computer-aided design and manufacturing techniques with assistance from surgical guides (surgical guide group, n = 25) or periapical x-rays (control group, n = 20). Insertion sites were selected using a 3-dimensional surgical planning program by fusing maxillary digital model images and cone-beam computed tomography images. Deviations between actual and planned placements were measured as 3-dimensional angular deviations and distance (coronal and apical) deviations. RESULTS: In the surgical guide group, the angular deviation was a median of 3.14° (range, 1.02°-10.9°), and the mesiodistal deviations in the coronal and apical areas were medians of 0.29 mm (range, 0.03-0.73 mm) and 0.21 mm (range, 0.03-0.97 mm), respectively. The deviations differed significantly between operators in the control group, but not in the surgical guide group. In the surgical guide group, there was no root damage from miniscrew placement, and 84% of the miniscrews were placed without contacting adjacent anatomic structures. In the control group, 50% of the miniscrews were placed between the roots (P <0.05). CONCLUSIONS: Surgical guide accuracy was improved when digital model imaging was used. Miniscrews were placed more accurately when using surgical guides than when using a direct method.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfAMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHBone Screws*-
dc.subject.MESHCadaver-
dc.subject.MESHComputer-Aided Design*-
dc.subject.MESHCone-Beam Computed Tomography/methods*-
dc.subject.MESHDental Models-
dc.subject.MESHEquipment Design-
dc.subject.MESHHumans-
dc.subject.MESHImage Processing, Computer-Assisted/methods-
dc.subject.MESHImaging, Three-Dimensional/methods-
dc.subject.MESHMaxilla/diagnostic imaging-
dc.subject.MESHMaxilla/surgery*-
dc.subject.MESHOrthodontic Anchorage Procedures/instrumentation*-
dc.subject.MESHOrthodontic Anchorage Procedures/methods-
dc.subject.MESHPatient Care Planning-
dc.subject.MESHRadiography, Bitewing/methods-
dc.subject.MESHSurgery, Computer-Assisted/methods*-
dc.subject.MESHTooth Root/diagnostic imaging-
dc.subject.MESHUser-Computer Interface-
dc.titleAccuracy of miniscrew surgical guides assessed from cone-beam computed tomography and digital models-
dc.typeArticle-
dc.contributor.collegeResearcher Institutes (부설 연구소)-
dc.contributor.department대학간연구소 개인식별연구소-
dc.contributor.googleauthorMi-Ju Bae-
dc.contributor.googleauthorJi-Young Kim-
dc.contributor.googleauthorJong-Tae Park-
dc.contributor.googleauthorJung-Yul Cha-
dc.contributor.googleauthorHee-Jin Kim-
dc.contributor.googleauthorHyung-Seog Yu-
dc.contributor.googleauthorChung-Ju Hwang-
dc.identifier.doi10.1016/j.ajodo.2013.02.018-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01225-
dc.contributor.localIdA02532-
dc.contributor.localIdA04006-
dc.contributor.localIdA04492-
dc.contributor.localIdA00983-
dc.contributor.localIdA01664-
dc.relation.journalcodeJ00098-
dc.identifier.eissn1097-6752-
dc.identifier.pmid23726340-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0889540613002606-
dc.subject.keywordBone Screws*-
dc.subject.keywordCadaver-
dc.subject.keywordComputer-Aided Design*-
dc.subject.keywordCone-Beam Computed Tomography/methods*-
dc.subject.keywordDental Models-
dc.subject.keywordEquipment Design-
dc.subject.keywordHumans-
dc.subject.keywordImage Processing, Computer-Assisted/methods-
dc.subject.keywordImaging, Three-Dimensional/methods-
dc.subject.keywordMaxilla/diagnostic imaging-
dc.subject.keywordMaxilla/surgery*-
dc.subject.keywordOrthodontic Anchorage Procedures/instrumentation*-
dc.subject.keywordOrthodontic Anchorage Procedures/methods-
dc.subject.keywordPatient Care Planning-
dc.subject.keywordRadiography, Bitewing/methods-
dc.subject.keywordSurgery, Computer-Assisted/methods*-
dc.subject.keywordTooth Root/diagnostic imaging-
dc.subject.keywordUser-Computer Interface-
dc.contributor.alternativeNameKim, Ji Young-
dc.contributor.alternativeNameKim, Hee Jin-
dc.contributor.alternativeNamePark, Jong Tae-
dc.contributor.alternativeNameYu, Hyung Seog-
dc.contributor.alternativeNameCha, Jung Yul-
dc.contributor.alternativeNameHwang, Chung Ju-
dc.contributor.affiliatedAuthorKim, Hee Jin-
dc.contributor.affiliatedAuthorYu, Hyung Seog-
dc.contributor.affiliatedAuthorCha, Jung Yul-
dc.contributor.affiliatedAuthorHwang, Chung Ju-
dc.contributor.affiliatedAuthorKim, Ji Young-
dc.contributor.affiliatedAuthorPark, Jong Tae-
dc.rights.accessRightsnot free-
dc.citation.volume143-
dc.citation.number6-
dc.citation.startPage893-
dc.citation.endPage901-
dc.identifier.bibliographicCitationAMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, Vol.143(6) : 893-901, 2013-
dc.identifier.rimsid32160-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Research Institute (부설연구소) > 1. Journal Papers
2. College of Dentistry (치과대학) > Research Institute (부설연구소) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Oral Biology (구강생물학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.