4 587

Cited 14 times in

Influence of peri-implant artifacts on bone morphometric analysis with micro-computed tomography

Authors
 Jin Wook Song  ;  Jung Yul Cha  ;  Till Edward Bechtold  ;  Young Chel Park 
Citation
 INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, Vol.28(2) : 519-525, 2013 
Journal Title
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
ISSN
 0882-2786 
Issue Date
2013
MeSH
Alveolar Process/diagnostic imaging* ; Alveolar Process/pathology ; Animals ; Artifacts* ; Bone Density* ; Dental Implant-Abutment Design ; Dental Implantation, Endosseous/methods* ; Dental Implants* ; Dental Restoration Failure ; Dilatation/methods ; Dogs ; Male ; Osseointegration* ; X-Ray Microtomography/methods
Keywords
artifact ; histomorphometry ; micro-computed tomography ; mini-implant
Abstract
Purpose: To determine the optimal dilation pixel size distance from the mini-implant interface needed to compensate for the metal artifact on micro–computed tomography (micro-CT) for bone morphometric analysis. Materials and Methods: A total of 72 self-drilling mini-implants were placed into the buccal alveolar bone of six male beagle dogs. After 12 weeks of orthodontic loading, specimens were harvested and scanned with micro-CT (Skyscan 1076) at a resolution of 9 μm. Using the reload plug-in and dilation procedure of CTAn, the percentage of bone-implant contact (BIC) and bone volume density (BV/TV, bone volume/total volume), respectively, were measured from one to seven pixels from the metal implant surface. Each pixel size of dilation (PSD) were compared with that of a ground histologic section, and the optimal PSD for bone morphometric analysis using micro-CT was determined. Results: BIC values from micro-CT analysis decreased when the PSD increased (P < .05). BIC from micro-CT showed the highest correlation coefficient with BIC from histologic slides when the PSD was 5 to 7 (P < .05), whereas BV/TV from micro-CT showed a very high correlation with BV/TV from histologic slides in all ranges (P < .0001). Conclusion: To measure BIC and BV/TV using micro-CT, at least 5 PSD from the metal implant surface is needed.
Full Text
http://www.quintpub.com/journals/omi/abstract.php?article_id=13014#.U3v2YqizIyo
DOI
10.11607/jomi.1632
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers
Yonsei Authors
Park, Young Chel(박영철)
Song, Jin Wook(송진욱)
Cha, Jung Yul(차정열)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/86532
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links