0 0

Cited 0 times in

Cited 0 times in

Impact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation

DC Field Value Language
dc.contributor.authorLee, Young Shin-
dc.contributor.authorUhm, Jae-Sun-
dc.contributor.authorPark, Je-Wook-
dc.contributor.authorPark, Seung-Jung-
dc.contributor.authorKim, Ye Chan-
dc.contributor.authorKim, In-Soo-
dc.contributor.authorLee, Hye-Jeong-
dc.contributor.authorKim, Moon-Hyun-
dc.contributor.authorPark, Hanjin-
dc.contributor.authorKim, Daehoon-
dc.contributor.authorYu, Hee Tae-
dc.contributor.authorKim, Tae-Hoon-
dc.contributor.authorKim, Jin-Bae-
dc.contributor.authorKim, Jong-Youn-
dc.contributor.authorJoung, Boyoung-
dc.contributor.authorPak, Hui-Nam-
dc.contributor.authorLee, Moon-Hyoung-
dc.date.accessioned2026-04-14T00:15:26Z-
dc.date.available2026-04-14T00:15:26Z-
dc.date.created2026-04-10-
dc.date.issued2026-03-
dc.identifier.issn0147-8389-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/211862-
dc.description.abstractIntroduction Leadless pacemakers are typically implanted in the mid-septum of the right ventricle (RV) to mitigate the risk of perforation. However, reports on the precise location of these implants are limited. This study aimed to elucidate tine-based leadless pacemaker position and presence of subclinical RV perforation through computed tomography (CT) imaging, along with the associated prognosis.Methods Patients who underwent heart, chest or abdomen CT after leadless pacemaker implantation were consecutively included. Two cardiologists and one radiologist reviewed the CT images to assess the position of tines and to detect RV perforation. The implantation position was categorized as the septum, RV free wall, junction of septum and RV free wall, moderator band, and RV apex. Subclinical perforation was defined as the tines of a leadless pacemaker beyond the outer myocardial contour without symptoms, pericardial effusion, hemodynamic instability, or pacemaker malfunction.Results A total of 88 patients (age, 72.9 +/- 12.1 years; 42 males) were included. The interval between procedure and CT scanning was 8.6 +/- 9.2 months. In 68 patients (77.3%), the leadless pacemaker was implanted at the junction of the septum and the RV free wall. Subclinical RV perforation occurred in 15 patients (17.0%). Among patients with RV perforation, the most common implantation site was the junction of the septum and the RV free wall. None of the patients with RV perforation experienced any adverse events for 12.4 +/- 12.3 months.Conclusions The most common leadless pacemaker implantation site is the junction of the septum and the RV free wall. Subclinical RV perforation is not uncommon and not associated with overt adverse outcomes.-
dc.languageEnglish-
dc.publisherFutura Pub. Co.-
dc.relation.isPartOfPACE-PACING AND CLINICAL ELECTROPHYSIOLOGY-
dc.relation.isPartOfPACE-PACING AND CLINICAL ELECTROPHYSIOLOGY-
dc.titleImpact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation-
dc.typeArticle-
dc.contributor.googleauthorLee, Young Shin-
dc.contributor.googleauthorUhm, Jae-Sun-
dc.contributor.googleauthorPark, Je-Wook-
dc.contributor.googleauthorPark, Seung-Jung-
dc.contributor.googleauthorKim, Ye Chan-
dc.contributor.googleauthorKim, In-Soo-
dc.contributor.googleauthorLee, Hye-Jeong-
dc.contributor.googleauthorKim, Moon-Hyun-
dc.contributor.googleauthorPark, Hanjin-
dc.contributor.googleauthorKim, Daehoon-
dc.contributor.googleauthorYu, Hee Tae-
dc.contributor.googleauthorKim, Tae-Hoon-
dc.contributor.googleauthorKim, Jin-Bae-
dc.contributor.googleauthorKim, Jong-Youn-
dc.contributor.googleauthorJoung, Boyoung-
dc.contributor.googleauthorPak, Hui-Nam-
dc.contributor.googleauthorLee, Moon-Hyoung-
dc.identifier.doi10.1111/pace.70218-
dc.relation.journalcodeJ02457-
dc.identifier.eissn1540-8159-
dc.identifier.pmid41906652-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/10.1111/pace.70218-
dc.subject.keywordartificial-
dc.subject.keywordpacemaker-
dc.subject.keywordpericardial effusion-
dc.subject.keywordtomography-
dc.subject.keywordX-ray computed-
dc.contributor.affiliatedAuthorUhm, Jae-Sun-
dc.contributor.affiliatedAuthorPark, Je-Wook-
dc.contributor.affiliatedAuthorKim, In-Soo-
dc.contributor.affiliatedAuthorLee, Hye-Jeong-
dc.contributor.affiliatedAuthorPark, Hanjin-
dc.contributor.affiliatedAuthorKim, Daehoon-
dc.contributor.affiliatedAuthorYu, Hee Tae-
dc.contributor.affiliatedAuthorKim, Tae-Hoon-
dc.contributor.affiliatedAuthorKim, Jong-Youn-
dc.contributor.affiliatedAuthorJoung, Boyoung-
dc.contributor.affiliatedAuthorPak, Hui-Nam-
dc.contributor.affiliatedAuthorLee, Moon-Hyoung-
dc.identifier.scopusid2-s2.0-105034593367-
dc.identifier.wosid001727235500001-
dc.identifier.bibliographicCitationPACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2026-03-
dc.identifier.rimsid92390-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorartificial-
dc.subject.keywordAuthorpacemaker-
dc.subject.keywordAuthorpericardial effusion-
dc.subject.keywordAuthortomography-
dc.subject.keywordAuthorX-ray computed-
dc.subject.keywordPlusCARDIAC PERFORATION-
dc.subject.keywordPlusEXPERIENCE-
dc.subject.keywordPlusPREDICTORS-
dc.subject.keywordPlusLEADS-
dc.type.docTypeArticle; Early Access-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalResearchAreaEngineering-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.