Abstract
Accurate range verification of carbon ion beams is critical for the precision and safety of charged particle radiotherapy. In this study, we evaluated the feasibility of using a parallel-plate ionization chamber for real-time, time-based diagnostic monitoring of carbon ion beams. The chamber featured a 0.4 mm gas gap defined by metallic electrodes and was filled with carbon dioxide (CO2), a non-polymerizing gas suitable for high-rate applications. Timing precision was assessed via self-correlation analysis, yielding a precision approaching 1 ps for 1 s acquisitions under clinically relevant beam conditions. This level of timing accuracy translates to a water-equivalent range uncertainty of approximately 1 mm, which meets the recommended clinical tolerance for carbon ion therapy. Furthermore, the kinetic energy of the beam at the synchrotron extraction point was determined from the measured orbital period, with results consistently within 1 MeV/nucleon of the nominal energy. These findings open the way to the use of parallel-plate chambers for precise, real-time energy and range verification in clinical carbon ion beam quality assurance.
Full Text
https://www.sciencedirect.com/science/article/pii/S016890022500871X
DOI
10.1016/j.nima.2025.171069
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
Yonsei Authors
Koom, Woong Sub(금웅섭) ORCID logo https://orcid.org/0000-0002-9435-7750
Kim, Dong Wook(김동욱) ORCID logo https://orcid.org/0000-0002-5819-9783
Kim, Jinsung(김진성) ORCID logo https://orcid.org/0000-0003-1415-6471
Kim, Changhwan(김창환)
Kim, Hojin(김호진) ORCID logo https://orcid.org/0000-0002-4652-8682
Lee, Ho(이호) ORCID logo https://orcid.org/0000-0001-5773-6893
Han, Min Cheol(한민철)
Han, Soorim(한수림)
Hong, Chae-Seon(홍채선) ORCID logo https://orcid.org/0000-0001-9120-6132
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/209651
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links