0 15

Cited 0 times in

Cited 0 times in

Quantitative and qualitative assessment of ultra-low-dose paranasal sinus CT using deep learning image reconstruction: a comparison with hybrid iterative reconstruction

Authors
 Otgonbaatar, Chuluunbaatar  ;  Lee, Dakyong  ;  Choi, Juneho  ;  Jang, Heijung  ;  Shim, Hackjoon  ;  Ryoo, Inseon  ;  Jung, Hye Na  ;  Suh, Sangil 
Citation
 EUROPEAN RADIOLOGY, 2025-06 
Journal Title
EUROPEAN RADIOLOGY
ISSN
 0938-7994 
Issue Date
2025-06
Keywords
Computed tomography ; Paranasal sinuses ; Image reconstruction ; Image quality
Abstract
Objectives This study aimed to evaluate the quantitative and qualitative performances of ultra-low-dose computed tomography (CT) with deep learning image reconstruction (DLR) compared with those of hybrid iterative reconstruction (IR) for preoperative paranasal sinus (PNS) imaging. Materials and methods This retrospective analysis included 132 patients who underwent non-contrast ultra-low-dose sinus CT (0.03 mSv). Images were reconstructed using hybrid IR and DLR. Objective image quality metrics, including image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), noise power spectrum (NPS), and no-reference perceptual image sharpness, were assessed. Two board-certified radiologists independently performed subjective image quality evaluations. Results The ultra-low-dose CT protocol achieved a low radiation dose (effective dose: 0.03 mSv). DLR showed significantly lower image noise (28.62 +/- 4.83 Hounsfield units) compared to hybrid IR (140.70 +/- 16.04, p < 0.001), with DLR yielding smoother and more uniform images. DLR demonstrated significantly improved SNR (22.47 +/- 5.82 vs 9.14 +/- 2.45, p < 0.001) and CNR (71.88 +/- 14.03 vs 11.81 +/- 1.50, p < 0.001). NPS analysis revealed that DLR reduced the noise magnitude and NPS peak values. Additionally, DLR demonstrated significantly sharper images (no-reference perceptual sharpness metric: 0.56 +/- 0.04) compared to hybrid IR (0.36 +/- 0.01). Radiologists rated DLR as superior in overall image quality, bone structure visualization, and diagnostic confidence compared to hybrid IR at ultra-low-dose CT. Conclusion DLR significantly outperformed hybrid IR in ultra-low-dose PNS CT by reducing image noise, improving SNR and CNR, enhancing image sharpness, and maintaining critical anatomical visualization, demonstrating its potential for effective preoperative planning with minimal radiation exposure.
Full Text
https://link.springer.com/article/10.1007/s00330-025-11763-2
DOI
10.1007/s00330-025-11763-2
Appears in Collections:
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers
Yonsei Authors
Shim, Hack Joon(심학준)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/208321
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links