12 141

Cited 0 times in

Long-term clinical and radiographic outcomes of a bone-level, 2-piece, internal connection implant system with coronal microthreads over 10 years of follow-up: a retrospective clinical study

Authors
 Young Woo Song  ;  Seung Ha Yoo  ;  Jin-Young Park  ;  Jae-Kook Cha  ;  Jeong-Won Paik  ;  Jung-Seok Lee  ;  Daniel S Thoma  ;  Ui-Won Jung 
Citation
 JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, Vol.55(2) : 153-166, 2025-04 
Journal Title
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE
ISSN
 2093-2278 
Issue Date
2025-04
Keywords
Clinical study ; Dental implant ; Implant survival ; Microthreads ; Peri-implant marginal bone level
Abstract
Purpose: This study retrospectively investigated the long-term clinical and radiographic outcomes of a bone-level type, 2-piece, internal connection dental implant system characterized by coronal microthreads.

Methods: A total of 872 implants placed in 284 patients were selected from 1,845 implants placed in 691 patients by experienced periodontists at Yonsei University Dental Hospital. These selected implants had been followed up for over 10 years and were included in the present study. A statistical evaluation of implant survival and treatment success, based on changes in marginal bone levels, was conducted using electronic records and consecutively taken radiographs.

Results: Over a follow-up period of 12.3±2.0 years, 830 of the 872 implants remained intact, yielding a cumulative survival rate of 95.2% at the implant level and 88.4% at the patient level. The cumulative treatment success rates, characterized by marginal bone loss of less than 2 mm, stood at 87.0% for implants and 76.1% for patients. Among the 830 surviving implants, 113 fixtures were classified as ailing, with an average marginal bone loss of 4.09±1.44 mm. Cox regression analysis revealed that implants 8 mm in length or shorter were significantly more likely to fail or experience pathologic marginal bone resorption, with hazard ratios of 3.71 and 2.00, respectively (P<0.05).

Conclusions: The survival and treatment success of the investigated microthreaded, bone-level, 2-piece, internal connection implants were acceptable over a follow-up period exceeding 10 years. However, shorter dental implants exhibited a higher propensity for failure and excessive marginal bone loss.
Files in This Item:
T202504831.pdf Download
DOI
10.5051/jpis.2401100055
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers
Yonsei Authors
Park, Jin Young(박진영)
Paik, Jeong Won(백정원) ORCID logo https://orcid.org/0000-0002-5554-8503
Lee, Jung Seok(이중석) ORCID logo https://orcid.org/0000-0003-1276-5978
Jung, Ui Won(정의원) ORCID logo https://orcid.org/0000-0001-6371-4172
Cha, Jae Kook(차재국) ORCID logo https://orcid.org/0000-0001-6817-9834
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/206698
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links