Cited 0 times in

Comparison of Volumetric Measurement Method With Region of Interest Drawing Method for Liver Fat Quantification

Authors
 Hyunji Lee  ;  Heejin Bae  ;  Ja Kyung Yoon  ;  June Park  ;  Yong Eun Chung 
Citation
 Investigative Magnetic Resonance Imaging, Vol.28(1) : 27-35, 2024-03 
Journal Title
Investigative Magnetic Resonance Imaging
ISSN
 2384-1095 
Issue Date
2024-03
Keywords
Non-alcoholic fatty liver disease ; Fat quantification ; Magnetic resonance imaging ; Proton density fat fraction ; Fatty liver
Abstract
Purpose: This study aimed to evaluate the feasibility of measuring liver fat using the volumetric measurement method (Fatvol) by comparing it with the conventional 27-regions of interest drawing method (Fatroi). Materials and Methods: This retrospective study included 67 patients who underwent liver magnetic resonance imaging with fat quantification in August or September 2020. Two experienced abdominal radiologists measured the proton density fat fraction (PDFF) of the liver using the mDIXON-Quant sequence for each of two methods. The PDFF was measured twice with each method at intervals of at least 4 weeks to avoid recall bias. Measurement times were recorded. The intra-class correlation coefficient (ICC) was calculated for intra-exam repeatability, inter-reviewer reproducibility, and inter-exam agreement. Results: Measurement times for Fatvol were significantly shorter than for Fatroi. Measurement times for Fatroi and Fatvol, respectively, for reviewer A were 209.4 ± 55.1 s and 137.2 ± 51.5 s in session 1, and 180.9 ± 37.3 s and 127.0 ± 46.1 s in session 2. For reviewer B, the times were 190.7 ± 30.1 s and 74.8 ± 27.4 s in session 1, and 174.6 ± 21.8 s and 64.1 ± 17.5 s in session 2. In all cases, p < 0.001. The mean PDFF values were 7.2% ± 6.4% and 7.2% ± 6.5% (sessions 1 and 2, respectively) for Fatroi and 7.4% ± 6.0% and 7.3% ± 6.1% for Fatvol for reviewer A. For reviewer B, they were 7.1% ± 6.6% and 7.1% ± 6.6% for Fatroi and 7.4% ± 5.8% and 7.4% ± 5.8% for Fatvol. The ICCs between measurement methods (0.998 and 0.995 for reviewers A and B, respectively), for Fatvol within each reviewer (0.999 and 1.000 in sessions 1 and 2, respectively), and between reviewers (0.999) were excellent. Conclusion: The measurement time could be significantly reduced using Fatvol compared to Fatroi while maintaining the consistency of the liver fat measurement values.
Files in This Item:
T202406135.pdf Download
DOI
10.13104/imri.2023.0020
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Bae, Heejin(배희진) ORCID logo https://orcid.org/0000-0002-1227-8646
Yoon, Ja Kyung(윤자경) ORCID logo https://orcid.org/0000-0002-3783-977X
Chung, Yong Eun(정용은) ORCID logo https://orcid.org/0000-0003-0811-9578
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/200938
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links