Effect of 5% albumin on endothelial glycocalyx degradation during off-pump coronary artery bypass

Authors
 Zhengyu Nan  ;  Sarah Soh  ;  Jae-Kwang Shim  ;  Hye Bin Kim  ;  Yun Seok Yang  ;  Young Lan Kwak  ;  Jong Wook Song 
Citation
 CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, Vol.71(2) : 244-253, 2024-03 
Journal Title
CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE
ISSN
 0832-610X 
Issue Date
2024-03
MeSH
Albumins ; Atrial Natriuretic Factor / metabolism ; Coronary Artery Bypass, Off-Pump* / adverse effects ; Crystalloid Solutions ; Gluconates ; Glycocalyx / metabolism ; Humans ; Magnesium Chloride ; Potassium Chloride ; Sodium Acetate ; Sodium Chloride ; Syndecan-1 / metabolism ; Thrombomodulin / metabolism
Keywords
albumin ; cardiac surgery ; fluid resuscitation ; glycocalyx ; syndecan-1 ; vascular homeostasis
Abstract
Purpose: The integrity of the endothelial glycocalyx (EG), a critical player in vascular homeostasis, reportedly influences the outcomes of critically ill patients. We investigated the effect of 5% albumin, which preserved EG integrity in preclinical studies, vs balanced crystalloid solution on EG degradation in patients undergoing off-pump coronary surgery.


Methods: Patients were randomized to receive either 5% albumin (N = 51) or balanced crystalloid solution (Plasma-Lyte [Baxter Incorporated, Seoul, Republic of Korea]; N = 53) for intravenous volume replacement during surgery (double-blinded). The primary outcome was plasma syndecan-1 concentration, a marker of EG degradation, measured after anesthetic induction (baseline), completion of grafting, and sternal closure. Secondary outcomes were atrial natriuretic peptide (ANP), tumour necrosis factor (TNF)-α, soluble thrombomodulin, and perioperative fluid balance.

Results: The mean (standard deviation) fluid requirements were 833 (270) mL and 1,323 (492) mL in the albumin and Plasma-Lyte group, respectively (mean difference, -489 mL; 95% confidence interval [CI], -643 to -335; P < 0.001). Plasma syndecan-1 concentration increased after completion of grafting (median difference, 116 ng·mL-1; 95% CI, 67 to 184; P < 0.001) and sternal closure (median difference, 57 ng·mL-1; 95% CI, 36 to 80; P < 0.001) compared with those at baseline, without any intergroup differences. Atrial natriuretic peptide, TNF-α, and soluble thrombomodulin concentrations were similar between the two groups. The amount of chest tube drainage was greater in the albumin group than that in the Plasma-Lyte group (median difference, 190 mL; 95% CI, 18 to 276; P = 0.03).

Conclusion: Off-pump coronary surgery was associated with significant EG degradation. Yet, intraoperative fluid therapy with 5% albumin could not ameliorate EG degradation when compared with balanced crystalloid solution.
Full Text
https://link.springer.com/article/10.1007/s12630-023-02652-7
DOI
10.1007/s12630-023-02652-7
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers
Yonsei Authors
Kwak, Young Lan(곽영란) ORCID logo https://orcid.org/0000-0002-2984-9927
Soh, Sa Rah(소사라) ORCID logo https://orcid.org/0000-0001-5022-4617
Song, Jong Wook(송종욱) ORCID logo https://orcid.org/0000-0001-7518-2070
Shim, Jae Kwang(심재광) ORCID logo https://orcid.org/0000-0001-9093-9692
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/198804
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links