Clinical Usefulness of Virtual Ablation Guided Catheter Ablation of Atrial Fibrillation Targeting Restitution Parameter-Guided Catheter Ablation: CUVIA-REGAB Prospective Randomized Study

Authors
 Young Choi  ;  Byounghyun Lim  ;  Song-Yi Yang  ;  So-Hyun Yang  ;  Oh-Seok Kwon  ;  Daehoon Kim  ;  Yun Gi Kim  ;  Je-Wook Park  ;  Hee Tae Yu  ;  Tae-Hoon Kim  ;  Pil-Sung Yang  ;  Jae-Sun Uhm  ;  Jamin Shim  ;  Sung Hwan Kim  ;  Jung-Hoon Sung  ;  Jong-Il Choi  ;  Boyoung Joung  ;  Moon-Hyoung Lee  ;  Young-Hoon Kim  ;  Yong-Seog Oh  ;  Hui-Nam Pak 
Citation
 KOREAN CIRCULATION JOURNAL, Vol.52(9) : 699-711, 2022-09 
Journal Title
KOREAN CIRCULATION JOURNAL
ISSN
 1738-5520 
Issue Date
2022-09
Keywords
Action potential ; Atrial fibrillation ; Catheter ablation ; Computer simulation ; Electrophysiology
Abstract
Background and objectives: We investigated whether extra-pulmonary vein (PV) ablation targeting a high maximal slope of the action potential duration restitution curve (Smax) improves the rhythm outcome of persistent atrial fibrillation (PeAF) ablation.

Methods: In this open-label, multi-center, randomized, and controlled trial, 178 PeAF patients were randomized with 1:1 ratio to computational modeling-guided virtual Smax ablation (V-Smax) or empirical ablation (E-ABL) groups. Smax maps were generated by computational modeling based on atrial substrate maps acquired during clinical procedures in sinus rhythm. Smax maps were generated during the clinical PV isolation (PVI). The V-Smax group underwent an additional extra-PV ablation after PVI targeting the virtual high Smax sites.

Results: After a mean follow-up period of 12.3±5.2 months, the clinical recurrence rates (25.6% vs. 23.9% in the V-Smax and the E-ABL group, p=0.880) or recurrence appearing as atrial tachycardia (11.1% vs. 5.7%, p=0.169) did not differ between the 2 groups. The post-ablation cardioversion rate was higher in the V-Smax group than E-ABL group (14.4% vs. 5.7%, p=0.027). Among antiarrhythmic drug-free patients (n=129), the AF freedom rate was 78.7% in the V-Smax group and 80.9% in the E-ABL group (p=0.776). The total procedure time was longer in the V-Smax group (p=0.008), but no significant difference was found in the major complication rates (p=0.497) between the groups.

Conclusions: Unlike a dominant frequency ablation, the computational modeling-guided V-Smax ablation did not improve the rhythm outcome of the PeAF ablation and had a longer procedure time.

Trial registration: ClinicalTrials.gov Identifier: NCT02558699.
Files in This Item:
T202204763.pdf Download
DOI
10.4070/kcj.2022.0113
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers
Yonsei Authors
Kwon, Oh-Seok(권오석)
Kim, Dae Hoon(김대훈) ORCID logo https://orcid.org/0000-0002-9736-450X
Kim, Tae-Hoon(김태훈) ORCID logo https://orcid.org/0000-0003-4200-3456
Park, Je Wook(박제욱)
Pak, Hui Nam(박희남) ORCID logo https://orcid.org/0000-0002-3256-3620
Uhm, Jae Sun(엄재선) ORCID logo https://orcid.org/0000-0002-1611-8172
Yu, Hee Tae(유희태) ORCID logo https://orcid.org/0000-0002-6835-4759
Lee, Moon-Hyoung(이문형) ORCID logo https://orcid.org/0000-0002-7268-0741
Lim, Byounghyun(임병현)
Joung, Bo Young(정보영) ORCID logo https://orcid.org/0000-0001-9036-7225
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/192074
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links