0 179

Cited 8 times in

Quality of science and reporting for radiomics in cardiac magnetic resonance imaging studies: a systematic review

Authors
 Suyon Chang  ;  Kyunghwa Han  ;  Young Joo Suh  ;  Byoung Wook Choi 
Citation
 EUROPEAN RADIOLOGY, Vol.32(7) : 4,361-4,373, 2022-07 
Journal Title
EUROPEAN RADIOLOGY
ISSN
 0938-7994 
Issue Date
2022-07
MeSH
Biomarkers ; Calibration ; Humans ; Magnetic Resonance Imaging* / methods ; Prognosis
Keywords
Heart ; Machine learning ; Magnetic resonance imaging ; Quality improvement
Abstract
Objectives: To evaluate the quality of radiomics studies using cardiac magnetic resonance imaging (CMR) according to the radiomics quality score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) guidelines, and the standards defined by the Image Biomarker Standardization Initiative (IBSI) and identify areas needing improvement.

Materials and methods: PubMed and Embase were searched to identify radiomics studies using CMR until March 10, 2021. Of the 259 identified articles, 32 relevant original research articles were included. Studies were scored according to the RQS, TRIPOD guidelines, and IBSI standards by two cardiac radiologists.

Results: The mean RQS was 14.3% of the maximum (5.16 out of 36). RQS were low for the demonstration of validation (-60.6%), calibration statistics (1.6%), potential clinical utility (3.1%), and open science (3.1%) items. No study conducted a phantom study or cost-effectiveness analysis. The adherence to TRIPOD guidelines was 55.9%. Studies were deficient in reporting title (3.1%), stating objective in abstract and introduction (6.3% and 9.4%), missing data (0%), discrimination/calibration (3.1%), and how to use the prediction model (3.1%). According to the IBSI standards, non-uniformity correction, image interpolation, grey-level discretization, and signal intensity normalization were performed in two (6.3%), four (12.5%), six (18.8%), and twelve (37.5%) studies, respectively.

Conclusion: The quality of radiomics studies using CMR is suboptimal. Improvements are needed in the areas of validation, calibration, clinical utility, and open science. Complete reporting of study objectives, missing data, discrimination/calibration, how to use the prediction model, and preprocessing steps are necessary.
Full Text
https://link.springer.com/article/10.1007/s00330-022-08587-9
DOI
10.1007/s00330-022-08587-9
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Suh, Young Joo(서영주) ORCID logo https://orcid.org/0000-0002-2078-5832
Chang, Su Yon(장수연)
Choi, Byoung Wook(최병욱) ORCID logo https://orcid.org/0000-0002-8873-5444
Han, Kyung Hwa(한경화)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/191658
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links