Abstract
Background/aim: The purpose of this study was to determine whether a semi-cylindrical beam spoiler (sCBS) developed herein effectively increases the skin dose in patients with early-stage glottic cancer.

Patients and methods: We measured the surface doses for 26 patients who used the sCBS during treatment of early-stage glottic cancer through a parallel-opposed lateral two-field 6 MV photon beam. Measurements were performed by attaching optically stimulated luminescent dosimeters to the left, right, anterior (in-field), inferior, and superior (out-field) sides of the patient.

Results: The measured results were 81.8±2.1% (left), 81.0±1.7% (right), and 76.8±2.7% (anterior) in the in-field region compared to prescription doses, with 5.7±1.7% (superior) and 2.7±0.7% (inferior) in the out-field region.

Conclusion: sCBS can deliver a suitably ideal surface dose for treatment of early-stage glottic cancer.
Files in This Item:
T202205354.pdf Download
DOI
10.21873/invivo.12795
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jinsung(김진성) ORCID logo https://orcid.org/0000-0003-1415-6471
Ahn, So Hyun(안소현)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/191287
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links