97 290

Cited 0 times in

Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors

Authors
 Sunyoung Lee  ;  Kyoung Won Kim  ;  So Yeon Kim  ;  Nieun Seo  ;  Gi-Won Song  ;  Sung-Gyu Lee 
Citation
 ULTRASONOGRAPHY, Vol.41(1) : 164-170, 2022-01 
Journal Title
ULTRASONOGRAPHY
ISSN
 2288-5919 
Issue Date
2022-01
Keywords
Controlled attenuation parameter ; Liver biopsy ; Living donors ; Macrovesicular steatosis ; Transient elastography
Abstract
Purpose: This study aimed to determine the diagnostic performance of the controlled attenuation parameter (CAP) measured using transient elastography (TE) for assessing macrovesicular steatosis (MaS) in potential living liver donors using same-day biopsy as a reference standard.

Methods: This retrospective study included 204 living liver donor candidates who underwent TE and liver biopsy on the same day between July 2013 and June 2014. The histologic degree of MaS was determined. The area under the receiver operating characteristic curve (AUROC) was used to evaluate the performance of CAP for diagnosing MaS of >10%, and the optimal cutoff value was identified using the maximal Youden index.

Results: Based on liver biopsy, 185 subjects had MaS of ≤10% and 19 had MaS of >10%. The CAP value was significantly correlated with the percentage of MaS on liver biopsy (r=0.635, P<0.001), and the median CAP value was significantly higher in subjects with MaS of >10% than in those with MaS of ≤10% (300 dB/m vs. 209 dB/m, P<0.001). The AUROC for diagnosing MaS of >10% by CAP was 0.938 (95% confidence interval, 0.896 to 0.967), and a CAP of >259 dB/m yielded a sensitivity of 84.2% and a specificity of 92.4%.

Conclusion: The CAP measured using TE was significantly correlated with MaS and accurately detected substantial MaS in potential living liver donors. The CAP is a promising tool for the noninvasive diagnosis of MaS and may be used to screen unsuitable living liver donor candidates.
Files in This Item:
T202200248.pdf Download
DOI
10.14366/usg.21071
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Seo, Nieun(서니은) ORCID logo https://orcid.org/0000-0001-8745-6454
Lee, Sunyoung(이선영) ORCID logo https://orcid.org/0000-0002-6893-3136
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/187905
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links