Cited 0 times in

국소적 간병변에 대한 자기공명영상에서의 고식적 스핀 에코 방식과 Fast Spin Echo 및 Fast Multiplanar SpoiledGradient Recalled 영상의 비교

Other Titles
 Comparison of Conventional Spin Echo, Fast Spin Echo and Fast Multiplanar Spoiled Gradient Recalled Imaging for Evaluation of Focal Hepatic Lesions. 
Authors
 최필석  ;  김명진  ;  김도중  ;  이종태  ;  유형식  ;  정재준 
Citation
 Journal of the Korean Radiologist Society (대한방사선의학회지), Vol.32(3) : 447-454, 1995-03 
Journal Title
Journal of the Korean Radiologist Society(대한방사선의학회지)
ISSN
 0301-2867 
Issue Date
1995-03
Abstract
PURPOSE: To compare the detectability and conspicuity of focal hepatic lesions among conventional spin echo techniqueniques and fast scanning techniqueniques in MR imaging. MATERIALS AND METHOD: 36 patients (24 men and 12 women, mean age of 54 years) with suspected liver mass on CT scan and US underwent MR imaging at 1.5 T system. Conventional spin echo T1, T2 weighted imaging, T2 weighted fast spin echo, T1 weighted fast multiplanar spoiled gradient recalled(FMPSPGR) imaging and Gd-enhanced FMPSPGR(Gd-FMPSPGR) were performed. 16 cases of hepatocellular carcinoma, 13 cases of hemangioma, 3 cases of metastasis, 3 cases of cholangiocarcinoma, and 1 case of lymphoma were included. Lesion conspicuity and number of detected hepatic masses were compared among the MR sequences. RESULTS: Overall 63 hepatic lesions were detected in 36 patients. Lesion detection' was 63(100%) with Gd-FMPSPGR, 62(98%) with non-enhanced FMPSPGR, 58(92%) with SE T2WI, 56(89%) with SE T1WI and 54 (86%)with FSE. For solid tumors, the contrast to noise ratio was greatest on Gd-FMPSPGR which was significantly higher than any other sequences. For hemangiomas it was greatest on SE T2WI and was significantly higher than SE T1WI. In the qualitative assessment, Gd-FMPSPGR was preferred for both solid mass lesion and hemangioma. FSE was inferior to SE T2WI for lesion detection and conspicuity without statistical significance. CONCLUSIONS: For the evaluation of focal hepatic lesions, breath-hold FMPSPGR with and without contrast enhancement may replace the conventional SE T1WI. Because FSE was inferior to SE T2WI when the later is used with respiratory compensation in some cases, it is difficult to replace the SE T2WI with FSE. But FSE, FMPSPGR and Gd-FMPSPGR images, when combined, may replace SE T1WI and SE T2WI.
Files in This Item:
T199501009.pdf Download
DOI
10.3348/jkrs.1995.32.3.447
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Myeong Jin(김명진) ORCID logo https://orcid.org/0000-0001-7949-5402
Chung, Jae Joon(정재준) ORCID logo https://orcid.org/0000-0002-7447-1193
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/186253
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links