288 443

Cited 0 times in

Energy Spectrum of Electromagnetic Radiation for a Dual-Energy Cone-Beam Computed Tomography in Radiotherapy

DC Field Value Language
dc.contributor.author김진성-
dc.contributor.author김소윤-
dc.date.accessioned2021-09-29T02:29:00Z-
dc.date.available2021-09-29T02:29:00Z-
dc.date.issued2020-12-
dc.identifier.issn1226-1750-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/184926-
dc.description.abstractTo implement dual-energy cone-beam computed tomography (CBCT), a 1 to 3 mm thick copper filter was applied in front of the kilovolt generator mounted on a medical linear accelerator. The energy calibration was performed from three energy peaks among the electromagnetic radiation, gamma rays, emitted by the 192Ir source. The energy spectrum was measured using a cadmium zinc telluride (CZT) detector. A figure-of-merit (FOM) value was defined and evaluated in order to consider both the increase in the mean energy and the decrease in the intensity according to the filter. For a 1 mm thick filter, the FOM values were 0.82 and 0.92 for tube voltages of 100 and 120 kVp, respectively. The intens ity was maintained reasonably and the effect of increasing the mean energy was evident, thus indicating its suitability for implementing dual-energy CBCT.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher한국자기학회-
dc.relation.isPartOfJOURNAL OF MAGNETICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEnergy Spectrum of Electromagnetic Radiation for a Dual-Energy Cone-Beam Computed Tomography in Radiotherapy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorSeunghyeop Baek-
dc.contributor.googleauthorJin Sung Kim-
dc.contributor.googleauthorWoo Sang Ahn-
dc.contributor.googleauthorSohyun Ahn-
dc.identifier.doi10.4283/JMAG.2020.25.4.614-
dc.contributor.localIdA04548-
dc.contributor.localIdA00623-
dc.relation.journalcodeJ03172-
dc.identifier.eissn2233-6656-
dc.subject.keywordelectromagnetic spectrum-
dc.subject.keywordCZT detector-
dc.subject.keyworddual-energy CBCT-
dc.subject.keywordenergy modulation filter-
dc.subject.keywordenergy in electro magnetic radiation-
dc.contributor.alternativeNameKim, Jinsung-
dc.contributor.affiliatedAuthor김진성-
dc.contributor.affiliatedAuthor김소윤-
dc.citation.volume25-
dc.citation.number4-
dc.citation.startPage614-
dc.citation.endPage619-
dc.identifier.bibliographicCitationJOURNAL OF MAGNETICS, Vol.25(4) : 614-619, 2020-12-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Humanities and Social Sciences (인문사회의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.