dc.description.abstract | Purpose : To determine the potential of spiral CT as a functional imaging modality of the lung asid from itsproven value in morphological depiction. Materials and Methods : Spiral CT scan was performed in ten normal femaleand nine normal male adults (mean age: 39, height: 163cm, weight: 62kg) after single full breath-holding. Threedimensional lung images were reconstructed (minimal threshold value: -1,000HU, maximal threshold values: -150,-250, -350, -450HU) to obtain total lung volume(TLV) on a histogram. Total lung volume measured by spiral CT wascompared with TLV obtained by spirometry. Results : Mean TLV measured by spirometry was 5.62 Land TLV measured byCT at maximal threshold values of -150, -250, -350, and -450HU was 6.63, 5.33, 5.15, and 4.98 L, respectively.Mean absolute differences between the modalities of 0.17L(3%), 0.32L(5.6%), 0.48L(8.5%), 0.65L(11.5) werestatistically significant(p<0.001). Linear regression coefficients between the modalities were 0.99, 0.97, 0.95,and 0.94 and no statistically significant differences in accuracy of threshold levels in the estimation of lungvolume(r=0.99, standard error=0.034L in all) were seen. Conclusion : TLV measured by spiral CT closelyapproximated that measured by spirometry. Spiral CT may be useful as a means of evaluating lung function. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한방사선의학회 | - |
dc.relation.isPartOf | Journal of the Korean Radiologist Society(대한방사선의학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Measurement of total lung capacity : A comparison of spiral CT and spirometry | - |
dc.title.alternative | 전폐 용적의 측정: 나선형의 CT와 폐활량 검사화의 비교 | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Anatomy (해부학교실) | - |
dc.contributor.googleauthor | Kyung Il Chung | - |
dc.contributor.googleauthor | Kyung Ju Park | - |
dc.contributor.googleauthor | Eh Hyung Lee | - |
dc.contributor.googleauthor | Kyu Ok Choe | - |
dc.contributor.googleauthor | Tae Hwan Lim | - |
dc.contributor.googleauthor | In Hyuk Chung | - |
dc.contributor.googleauthor | Heun Young Yune | - |
dc.contributor.googleauthor | Jung Ho Suh | - |
dc.identifier.doi | 10.3348/jkrs.1996.35.2.189 | - |
dc.contributor.localId | A03697 | - |
dc.contributor.localId | A04042 | - |
dc.relation.journalcode | J01844 | - |
dc.subject.keyword | Lung, volume | - |
dc.subject.keyword | Lung, function | - |
dc.subject.keyword | Lung, CT | - |
dc.subject.keyword | Computed tomography(CT), helical technology | - |
dc.contributor.alternativeName | Chung, In Hyuk | - |
dc.contributor.affiliatedAuthor | 정인혁 | - |
dc.contributor.affiliatedAuthor | 최규옥 | - |
dc.citation.volume | 35 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 189 | - |
dc.citation.endPage | 193 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Radiologist Society (대한방사선의학회지), Vol.35(2) : 189-193, 1996-08 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.