340 545

Cited 10 times in

Cited 13 times in

Accuracy of Implant Position Reproduction According to Exposed Length of the Scan Body during Optical Scanning: An In Vitro Study

Authors
 Nam, Na-Eun  ;  Shin, Seung-Ho  ;  Lim, Jung-Hwa  ;  Lee, Bora  ;  Shim, June-Sung  ;  Kim, Jong-Eun 
Citation
 APPLIED SCIENCES-BASEL, Vol.11(4) : 1-16, 2021-02 
Article Number
 1689 
Journal Title
APPLIED SCIENCES-BASEL
ISSN
 2076-3417 
Issue Date
2021-02
Keywords
digital impression ; implant scan body ; intraoral scanner
Abstract
Featured Application This paper's application is in the proposal of a guideline for predicting and preventing errors that may occur during the image matching process when using Dental CAD software for implant prosthesis. The differences in the accuracy of implant position reproduction according to various types of scanners, implant placement depths, and tooth positions are presented in detail. Accuracy of implant position reproduction according to various types of scanners, implant placement depths, and tooth positions are unknown. The purpose of this study was to compare the accuracy of implant position reproduction for differences in the exposed length of the implant scan body according to scanner type and tooth position. Implants were placed at the positions of the lateral incisor, first premolar, and first molar in the study model at the bone level and submerged 1.5 mm, 3.0 mm, 4.5 mm, and 6.0 mm. The completed models were scanned with one type of tabletop scanner and three types of intraoral scanners (TRIOS 3, i500, and CS3600). A matching process was performed for all scan data to superimpose abutment library data on the scan body, and the root mean square errors were analyzed in three dimensions to evaluate the position reproducibility of the replaced abutment library. In the trueness analysis, the error increased rapidly for an implant placement depth of 4.5 mm, and was largest for a submersion of 6.0 mm. The precision analysis confirmed that the error increased for depths of at least 3.0 mm. The analysis by position identified that the accuracy was lowest for an implant placed at the position of the lateral incisor. These findings indicate that special care is required when making an impression of a deep implant with an optical scanner.
DOI
10.3390/app11041689
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Dental Education (치의학교육학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jong Eun(김종은) ORCID logo https://orcid.org/0000-0002-7834-2524
Shim, June Sung(심준성) ORCID logo https://orcid.org/0000-0003-1428-0122
Lee, Bora(이보라) ORCID logo https://orcid.org/0000-0002-1162-9803
Lim, Jung-Hwa(임정화)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/182114
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links