251 460

Cited 19 times in

Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison With Cardiac MRI: A Meta-Analysis

Authors
 Jin Young Kim  ;  Young Joo Suh  ;  Kyunghwa Han  ;  Young Jin Kim  ;  Byoung Wook Choi 
Citation
 KOREAN JOURNAL OF RADIOLOGY, Vol.21(4) : 450-461, 2020-04 
Journal Title
KOREAN JOURNAL OF RADIOLOGY
ISSN
 1229-6929 
Issue Date
2020-04
Keywords
Computed tomography ; Magnetic resonance imaging ; Meta-analysis ; Right ventricular function ; Volumetry
Abstract
Objective: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters.

Materials and methods: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods.

Results: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (-5.7 to 11.8 mL), 3.6 mL (-4.0 to 11.2 mL), -0.4 mL (5.7 to 5.0 mL), and -1.8% (-5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87-0.93). Heterogeneity was observed in the studies (I² > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA.

Conclusion: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.
Files in This Item:
T202001207.pdf Download
DOI
10.3348/kjr.2019.0499
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Young Jin(김영진) ORCID logo https://orcid.org/0000-0002-6235-6550
Suh, Young Joo(서영주) ORCID logo https://orcid.org/0000-0002-2078-5832
Choi, Byoung Wook(최병욱) ORCID logo https://orcid.org/0000-0002-8873-5444
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/176036
사서에게 알리기