375 903

Cited 17 times in

Cited 17 times in

Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay

Authors
 Kim, Jin Ju  ;  Park, Younhee  ;  Choi, Dasom  ;  Kim, Hyon-Suk 
Citation
 ANNALS OF LABORATORY MEDICINE, Vol.40(1) : 33-39, 2020-01 
Journal Title
ANNALS OF LABORATORY MEDICINE
ISSN
 2234-3806 
Issue Date
2020-01
Keywords
Performance ; Interferon-gamma releasing assay ; Latent tuberculosis infection ; Chemiluminescent immunoanalyzer ; QuantiFERON-TB Gold In-Tube
Abstract
Background: The interferon-gamma (IFN-gamma) releasing assay (IGRA) is widely used for latent tuberculosis infection (LTBI) diagnosis. We evaluated the analytical performance of a new automated chemiluminescent immunoanalyzer-based IGRA (CLIA-IGRA), AdvanSure I3 (LG Life Sciences, Seoul, Korea) and compared it with that of the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay. Methods: Repeatability and reproducibility were evaluated at four levels. Detection capability, including limit of blank (LoB), limit of detection (LoD), and limit of quantification (LoQ), was evaluated using IFN-gamma standard material (National Institute for Biological Standards and Control code: 87/586). Agreement between the results of two assays was evaluated using 341 blood samples from healthcare workers and patients at a tertiary care hospital. To determine the cut-off value of CLIA-IGRA for diagnosing LTBI, the ROC curve was analyzed. Results: Repeatability and reproducibility were 4.86-7.00% and 6.36-7.88% CV, respectively. LoB, LoD, and LoQ were 0.022, 0.077, and 0.249 IU/mL, respectively. IFN-gamma values between CLIA-IGRA and QFT-GIT showed a strong correlation within the analytical measurable range of both assays, especially when the value was low. Qualitative comparison of the two assays yielded a 99.1% overall agreement (kappa coefficient=0.98). A cut-off value of 0.35 IU/mL was appropriate for diagnosing LTBI. Conclusions: CLIA-IGRA is a reliable assay for LTBI diagnosis, with performance similar to that of QFT-GIT.
DOI
10.3343/alm.2020.40.1.33
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jin Ju(김진주) ORCID logo https://orcid.org/0000-0001-9166-1848
Kim, Hyon Suk(김현숙) ORCID logo https://orcid.org/0000-0001-5662-7740
Park, Youn Hee(박윤희) ORCID logo https://orcid.org/0000-0001-8458-1495
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/174904
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links