375 903

Cited 17 times in

Cited 17 times in

Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay

DC Field Value Language
dc.contributor.authorKim, Jin Ju-
dc.contributor.authorPark, Younhee-
dc.contributor.authorChoi, Dasom-
dc.contributor.authorKim, Hyon-Suk-
dc.date.accessioned2020-02-11T06:55:47Z-
dc.date.available2020-02-11T06:55:47Z-
dc.date.created2021-03-18-
dc.date.issued2020-01-
dc.identifier.issn2234-3806-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/174904-
dc.description.abstractBackground: The interferon-gamma (IFN-gamma) releasing assay (IGRA) is widely used for latent tuberculosis infection (LTBI) diagnosis. We evaluated the analytical performance of a new automated chemiluminescent immunoanalyzer-based IGRA (CLIA-IGRA), AdvanSure I3 (LG Life Sciences, Seoul, Korea) and compared it with that of the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay. Methods: Repeatability and reproducibility were evaluated at four levels. Detection capability, including limit of blank (LoB), limit of detection (LoD), and limit of quantification (LoQ), was evaluated using IFN-gamma standard material (National Institute for Biological Standards and Control code: 87/586). Agreement between the results of two assays was evaluated using 341 blood samples from healthcare workers and patients at a tertiary care hospital. To determine the cut-off value of CLIA-IGRA for diagnosing LTBI, the ROC curve was analyzed. Results: Repeatability and reproducibility were 4.86-7.00% and 6.36-7.88% CV, respectively. LoB, LoD, and LoQ were 0.022, 0.077, and 0.249 IU/mL, respectively. IFN-gamma values between CLIA-IGRA and QFT-GIT showed a strong correlation within the analytical measurable range of both assays, especially when the value was low. Qualitative comparison of the two assays yielded a 99.1% overall agreement (kappa coefficient=0.98). A cut-off value of 0.35 IU/mL was appropriate for diagnosing LTBI. Conclusions: CLIA-IGRA is a reliable assay for LTBI diagnosis, with performance similar to that of QFT-GIT.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKorean Society for Laboratory Medicine-
dc.relation.isPartOfANNALS OF LABORATORY MEDICINE-
dc.relation.isPartOfANNALS OF LABORATORY MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titlePerformance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorKim, Jin Ju-
dc.contributor.googleauthorPark, Younhee-
dc.contributor.googleauthorChoi, Dasom-
dc.contributor.googleauthorKim, Hyon-Suk-
dc.identifier.doi10.3343/alm.2020.40.1.33-
dc.relation.journalcodeJ00164-
dc.identifier.eissn2234-3814-
dc.identifier.pmid31432637-
dc.subject.keywordPerformance-
dc.subject.keywordInterferon-gamma releasing assay-
dc.subject.keywordLatent tuberculosis infection-
dc.subject.keywordChemiluminescent immunoanalyzer-
dc.subject.keywordQuantiFERON-TB Gold In-Tube-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.affiliatedAuthorKim, Jin Ju-
dc.contributor.affiliatedAuthorPark, Younhee-
dc.contributor.affiliatedAuthorKim, Hyon-Suk-
dc.identifier.scopusid2-s2.0-85071774318-
dc.identifier.wosid000490017200006-
dc.citation.volume40-
dc.citation.number1-
dc.citation.startPage33-
dc.citation.endPage39-
dc.identifier.bibliographicCitationANNALS OF LABORATORY MEDICINE, Vol.40(1) : 33-39, 2020-01-
dc.identifier.rimsid68502-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorPerformance-
dc.subject.keywordAuthorInterferon-gamma releasing assay-
dc.subject.keywordAuthorLatent tuberculosis infection-
dc.subject.keywordAuthorChemiluminescent immunoanalyzer-
dc.subject.keywordAuthorQuantiFERON-TB Gold In-Tube-
dc.subject.keywordPlusLATENT TUBERCULOSIS INFECTION-
dc.subject.keywordPlusENZYME-IMMUNOASSAY-
dc.subject.keywordPlusDIAGNOSIS-
dc.subject.keywordPlusPLUS-
dc.subject.keywordPlusMETAANALYSIS-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalWebOfScienceCategoryMedical Laboratory Technology-
dc.relation.journalResearchAreaMedical Laboratory Technology-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.