무수치 표백술에서 근관내 Base가 표백약제의 누출 방지에 미치는 영향

Other Titles
 THE EFFECT OF INTRACANAL BASE ON PREVENTION OF APICAL LEAKAGE OF BLEACHING AGENTS 
Authors
 최승호  ;  노병덕  ;  박성호  ;  이승종 
Citation
 Journal of Korean Academy of Operative Dentistry (대한치과보존학회지), Vol.24(3) : 453-464, 1999 
Journal Title
Journal of Korean Academy of Operative Dentistry(대한치과보존학회지)
ISSN
 1225-0864 
Issue Date
1999
Keywords
Non-vital bleaching ; Microleakage ; Cervical external root resorption ; Base ; Tubuli seal® ; AH-26® ; Dentin cement® ; IRM®
Abstract
The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal(R)(Kerr Co., USA) was used in 39 teeth and in others, AH-26(R)(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal(R) were divided into two groups, and Dentin cement(R)(GC corp., Japan) and JRM(R)(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26(R) as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement(R) and IRM(R) group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.
Files in This Item:
T199901437.pdf Download
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers
Yonsei Authors
Lee, Seung Jong(이승종)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/172640
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links