317 412

Cited 0 times in

전자선 단층 촬영을 이용한 심근 관류 측정

DC Field Value Language
dc.contributor.author강희철-
dc.contributor.author이승구-
dc.date.accessioned2019-11-11T05:55:09Z-
dc.date.available2019-11-11T05:55:09Z-
dc.date.issued2000-
dc.identifier.issn0301-2867-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/172259-
dc.description.abstractPurpose: To compare the accuracy with which electron beam tomography (EBT) and 99mTc-MIBI scanning measure myocardial perfusion valve. Materials and Methods: Twenty-two subjects [normal volunteers (n = 6), patients in whom ischemic heart disease was diagnosed (n = 5), and those in whom ischemic heart disease was suspected but who were found to be normal (n = 11)] were involved in this study. EBT was performed after bolus injection of contrast media (50 ml of IopamiroⓇ 370 or OptirayⓇ 350, 3 ml/sec). The myocardium was divided into 16 segments according to the classification devised by the American Society of Echocardiography, and each myocardial perfusion value was calculated by post-image processing. A pharmacologic stress test was performed in all subjects except four patients with acute myocardial infarction, and myocardial perfusion reserve ratios were assessed. Single photon emission computed tomography (SPECT) was performed after the injection of 20 mCi of 99mTc-MIBI. Any segments with moderate to severe photon defect on visual analysis of SPECT were identified and perfusion values determined by EBT in normal and ischemic segments were compared. Results: No difference in myocardial perfusion was found between volunteers and the suspected group. Their perfusion values were 0.71±0.14 ml/g/min in the resting state and 1.16±0.24 ml/g/min on the stress test and the myocardial perfusion reserve ratio was, therefore, 1:1.68±0.38. In ischemic patients, 99mTc-MIBI scanning revealed a perfusion defect in 28 segments, and on EBT the measurement obtained was 0.54±0.19 ml/g/min. The remaining 324 perfusion segments shown by SPECT to be normal showed a perfusion value of 0.79±0.22 ml/g/min on EBT. Conclusion: Compared with 99mTc-MIBI scanning, the measurement of myocardial perfusion by EBT provides absolute quantification of perfusion value and more detailed anatomic information.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한방사선의학회-
dc.relation.isPartOfJournal of the Korean Radiological Society (대한방사선의학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title전자선 단층 촬영을 이용한 심근 관류 측정-
dc.title.alternativeMeasurement of Myocardial Perfusion with Electron Beam Tomography: Comparison with 99mTc-MIBI Scan1-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Family Medicine (가정의학교실)-
dc.contributor.googleauthor이승구-
dc.contributor.googleauthor최진영-
dc.contributor.googleauthor유석종-
dc.contributor.googleauthor최병욱-
dc.contributor.googleauthor전태주-
dc.contributor.googleauthor이종두-
dc.contributor.googleauthor허갑범-
dc.contributor.googleauthor송영득-
dc.contributor.googleauthor윤방부-
dc.contributor.googleauthor강희철-
dc.contributor.googleauthor최규옥-
dc.identifier.doi10.3348/jkrs.2000.43.1.31-
dc.contributor.localIdA00105-
dc.contributor.localIdA02912-
dc.relation.journalcodeJ01844-
dc.subject.keywordMyocardium, blood supply-
dc.subject.keywordMyocardium, Electron Beam Tomography-
dc.subject.keywordMyocardium, 99mTc-MIBI scan-
dc.subject.keywordMyocardium, ischemia-
dc.contributor.alternativeNameKang, Hee Cheol-
dc.contributor.affiliatedAuthor강희철-
dc.contributor.affiliatedAuthor이승구-
dc.citation.volume43-
dc.citation.number1-
dc.citation.startPage31-
dc.citation.endPage37-
dc.identifier.bibliographicCitationJournal of the Korean Radiological Society (대한방사선의학회지), Vol.43(1) : 31-37, 2000-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Family Medicine (가정의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.