0 618

Cited 24 times in

Detection of vertebral metastases: a comparison between the modified Dixon turbo spin echo T2 weighted MRI and conventional T1 weighted MRI: a preliminary study in a tertiary centre

Authors
 Seok Hahn  ;  Young Han Lee  ;  Jin-Suck Suh 
Citation
 BRITISH JOURNAL OF RADIOLOGY, Vol.91(1085) : 20170782, 2018 
Journal Title
BRITISH JOURNAL OF RADIOLOGY
ISSN
 0007-1285 
Issue Date
2018
MeSH
Adult ; Aged ; 80 and over Aged ; Female ; Humans ; Computer-Assisted/*methods Image Processing ; Magnetic Resonance Imaging/*methods ; Male ; Middle Aged ; Retrospective Studies ; Sensitivity and Specificity ; Spinal Neoplasms/*diagnostic imaging/secondary ; Spine/*diagnostic imaging/*pathology ; Tertiary Care Centers
Abstract
OBJECTIVE: To compare the diagnostic performance of modified Dixon (mDixon) turbo spin echo (TSE) T2 weighted MRI and conventional T1 weighted MRI in vertebral metastasis detection. METHODS: Between September 2014 and October 2016, 33 patients with 68 metastases who had undergone whole-spine MRI were enrolled. The following sagittal image sets were evaluated: T1WI, and mDixon TSE T2 weighted water and fat images. Two radiologists independently evaluated each image-set for metastasis. The MR findings were compared with positron emission tomography-CT (PET-CT) scans. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each sequence. The diagnostic performance of each sequence was evaluated using receiver operating characteristic (ROC) curves. RESULTS: Sensitivity, specificity, PPV and NPV for reviewer 1 were 83.8, 99.1, 89.1 and 98.6%, respectively, with T1WI; 79.4, 98.8, 85.7 and 98.2%, respectively, with mDixon TSE T2 weighted water imaging; and 86.8, 99.1, 89.4 and 98.8%, respectively, with mDixon TSE T2 weighted fat imaging. For reviewer 2, the respective scores were 91.2, 99.2, 91.2 and 99.2%; 85.3, 99.5, 93.4 and 98.7%; and 89.7, 99.3, 92.4 and 99.1%. With PET-CT as the gold standard, the ROC curves of the three sequences showed no significant difference (all p > 0.05). CONCLUSION: The diagnostic performance of mDixon TSE T2 weighted water and fat imaging was comparable to that of conventional T1WI in the detection of vertebral metastases. Advances in knowledge: mDixon TSE T2WI can be a good alternative to conventional T1WI for detecting vertebral metastases.
Full Text
https://www.birpublications.org/doi/10.1259/bjr.20170782
DOI
10.1259/bjr.20170782
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Suh, Jin Suck(서진석) ORCID logo https://orcid.org/0000-0001-9455-9240
Lee, Young Han(이영한) ORCID logo https://orcid.org/0000-0002-5602-391X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/162641
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links