Cited 35 times in
Measuring water contents in animal organ tissues using terahertz spectroscopic imaging
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 서진석 | - |
dc.contributor.author | 손혜영 | - |
dc.contributor.author | 오승재 | - |
dc.contributor.author | 지영빈 | - |
dc.contributor.author | 허용민 | - |
dc.date.accessioned | 2018-08-28T17:02:54Z | - |
dc.date.available | 2018-08-28T17:02:54Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/162200 | - |
dc.description.abstract | We investigated the water contents in several organ tissues such as the liver, spleen, kidney, and brain tissue of rats using the terahertz spectroscopic imaging technique. The water contents of the tissues were determined by using a simple equation containing the absorption coefficients of fresh and lyophilized tissues and water. We compared the measured water contents with the difference in mass of tissues before and after lyophilization. All results showed a good match except for the kidney, which has several Bowman's capsules. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Optical Society of America | - |
dc.relation.isPartOf | BIOMEDICAL OPTICS EXPRESS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Measuring water contents in animal organ tissues using terahertz spectroscopic imaging | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Radiology | - |
dc.contributor.googleauthor | Kyumin Lee | - |
dc.contributor.googleauthor | Kiyong Jeoung | - |
dc.contributor.googleauthor | Sang Hoon Kim | - |
dc.contributor.googleauthor | Young-Bin Ji | - |
dc.contributor.googleauthor | Hyeyoung Son | - |
dc.contributor.googleauthor | Yuna Choi | - |
dc.contributor.googleauthor | Young-Min Huh | - |
dc.contributor.googleauthor | Jin-Suck Suh | - |
dc.contributor.googleauthor | Seung Jae Oh | - |
dc.identifier.doi | 10.1364/boe.9.001582 | - |
dc.contributor.localId | A01916 | - |
dc.contributor.localId | A04589 | - |
dc.contributor.localId | A02383 | - |
dc.contributor.localId | A04687 | - |
dc.contributor.localId | A04359 | - |
dc.relation.journalcode | J00320 | - |
dc.identifier.eissn | 2156-7085 | - |
dc.identifier.pmid | 29675303 | - |
dc.subject.keyword | (170.3880) Medical and biological imaging | - |
dc.subject.keyword | (170.4580) Optical diagnostics for medicine | - |
dc.subject.keyword | tissue diagnostics (170.6510) Spectroscopy | - |
dc.subject.keyword | (170.6795) Terahertz imaging | - |
dc.subject.keyword | terahertz (300.6495) Spectroscopy | - |
dc.contributor.alternativeName | Suh, Jin Suck | - |
dc.contributor.alternativeName | Son, Hye Yeong | - |
dc.contributor.alternativeName | Oh, Seung Jae | - |
dc.contributor.alternativeName | Ji, Young Bin | - |
dc.contributor.alternativeName | Huh, Yong Min | - |
dc.contributor.affiliatedAuthor | Suh, Jin Suck | - |
dc.contributor.affiliatedAuthor | Son, Hye Yeong | - |
dc.contributor.affiliatedAuthor | Oh, Seung Jae | - |
dc.contributor.affiliatedAuthor | Ji, Young Bin | - |
dc.contributor.affiliatedAuthor | Huh, Yong Min | - |
dc.citation.volume | 9 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 1582 | - |
dc.citation.endPage | 1589 | - |
dc.identifier.bibliographicCitation | BIOMEDICAL OPTICS EXPRESS, Vol.9(4) : 1582-1589, 2018 | - |
dc.identifier.rimsid | 59786 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.