dc.description.abstractPURPOSE: To investigate the optimal magnetic resonance (MR) imaging protocol in pregnant women suspected of having acute appendicitis. MATERIALS AND METHODS: One hundred and forty-six pregnant women with suspected appendicitis were included. MR images were reviewed by two radiologists in three separate sessions. In session 1, only axial single-shot turbo spin echo (SSH-TSE) T2-weighted images (WI) were included with other routine sequences. In sessions 2 and 3, coronal and sagittal T2WI were sequentially added. The visibility of the appendix and diagnostic confidence of appendicitis were evaluated in each session using a 5-point grading scale. If diseases other than appendicitis were suspected, specific diagnosis with a 5-point confidence scale was recorded. Diagnostic performance for appendicitis and other diseases were evaluated. RESULTS: Twenty-five patients (17.1%) were diagnosed with appendicitis. Among the patients with normal appendix, 28 were diagnosed with other disease. Diagnostic performance including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the curve values for diagnosing appendicitis and other diseases showed no significant difference among sets for both reviewers (p>0.05). CONCLUSION: Diagnostic performance of MR in pregnant patients with suspected appendicitis can be preserved with omission of sagittal or both coronal and sagittal SSH-T2WI. KEY POINTS: * Diagnostic performance of appendicitis is preserved with omission of sagittal/coronal T2WIs. * Diagnosis of other disease may be sufficient with axial T2WIs only. * Careful serial omission of sagittal and coronal T2WIs can be considered.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSpringer International-
dc.relation.isPartOfEUROPEAN RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAcute Disease-
dc.subject.MESHAdult-
dc.subject.MESHAppendicitis/*diagnosis-
dc.subject.MESHAppendix/*pathology-
dc.subject.MESHDifferential Diagnosis-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMagnetic Resonance Imaging/*methods-
dc.subject.MESHPregnancy-
dc.subject.MESHPregnancy Complications/*diagnosis-
dc.subject.MESHPrenatal Diagnosis/*methods-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHYoung Adult-
dc.titleOptimisation of the MR protocol in pregnant women with suspected acute appendicitis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Radiology-
dc.contributor.googleauthorIlah Shin-
dc.contributor.googleauthorYong Eun Chung-
dc.contributor.googleauthorChansik An-
dc.contributor.googleauthorHye Sun Lee-
dc.contributor.googleauthorHonsoul Kim-
dc.contributor.googleauthorJoon Seok Lim-
dc.contributor.googleauthorMyeong-Jin Kim-
dc.identifier.doi10.1007/s00330-017-5038-y-
dc.contributor.localIdA00426-
dc.contributor.localIdA01099-
dc.contributor.localIdA02268-
dc.contributor.localIdA03312-
dc.contributor.localIdA03408-
dc.contributor.localIdA03662-
dc.relation.journalcodeJ00851-
dc.identifier.eissn1432-1084-
dc.identifier.pmid28894912-
dc.identifier.urlhttps://link.springer.com/article/10.1007%2Fs00330-017-5038-y-
dc.subject.keywordAbdomen-
dc.subject.keywordAbdominal pain-
dc.subject.keywordAcute-
dc.subject.keywordAppendicitis-
dc.subject.keywordMagnetic resonance imaging-
dc.subject.keywordPregnancy-
dc.contributor.alternativeNameKim, Myeong Jin-
dc.contributor.alternativeNameKim, Hon Soul-
dc.contributor.alternativeNameAn, Chan Sik-
dc.contributor.alternativeNameLee, Hye Sun-
dc.contributor.alternativeNameLim, Joon Seok-
dc.contributor.alternativeNameChung, Yong Eun-
dc.contributor.affiliatedAuthorKim, Myeong Jin-
dc.contributor.affiliatedAuthorKim, Hon Soul-
dc.contributor.affiliatedAuthorAn, Chan Sik-
dc.contributor.affiliatedAuthorLee, Hye Sun-
dc.contributor.affiliatedAuthorLim, Joon Seok-
dc.contributor.affiliatedAuthorChung, Yong Eun-
dc.citation.volume28-
dc.citation.number2-
dc.citation.startPage514-
dc.citation.endPage521-
dc.identifier.bibliographicCitationEUROPEAN RADIOLOGY, Vol.28(2) : 514-521, 2018-
dc.identifier.rimsid59607-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.