0 594

Cited 54 times in

Application of Computer-Aided Diagnosis on Breast Ultrasonography: Evaluation of Diagnostic Performances and Agreement of Radiologists According to Different Levels of Experience

Authors
 Eun Cho  ;  Eun-Kyung Kim  ;  Mi Kyung Song  ;  Jung Hyun Yoon 
Citation
 JOURNAL OF ULTRASOUND IN MEDICINE, Vol.37(1) : 209-216, 2018 
Journal Title
JOURNAL OF ULTRASOUND IN MEDICINE
ISSN
 0278-4297 
Issue Date
2018
Keywords
Breast Imaging Reporting and Data System ; breast ; computer-aided diagnosis ; neoplasm ; ultrasonography ; ultrasound equipment and products
Abstract
OBJECTIVES: To investigate the feasibility of a computer-aided diagnosis (CAD) system (S-Detect; Samsung Medison, Co, Ltd, Seoul, Korea) for breast ultrasonography (US), according to radiologists with various degrees of experience in breast imaging. METHODS: From December 2015 to March 2016, 119 breast masses in 116 women were included. Ultrasonographic images of the breast masses were retrospectively reviewed and analyzed by 2 radiologists specializing in breast imaging (7 and 1 years of experience, respectively) and S-Detect, according to the individual ultrasonographic descriptors from the fifth edition of the American College of Radiology Breast Imaging Reporting and Data System and final assessment categories. Diagnostic performance and the interobserver agreement among the radiologists and S-Detect was calculated and compared. RESULTS: Among the 119 breast masses, 54 (45.4%) were malignant, and 65 (54.6%) were benign. Compared to the radiologists, S-Detect had higher specificity (90.8% compared to 49.2% and 55.4%) and positive predictive value (PPV; 86.7% compared to 60.7% and 63.8%) (all P < .001). Both radiologists had significantly improved specificity, PPV, and accuracy when using S-Detect compared to US alone (all P < .001). The area under the receiving operating characteristic curves of the both radiologists did not show a significant improvement when applying S-Detect compared to US alone (all P > .05). Moderate agreement was seen in final assessments made by each radiologist and S-Detect (kappa = 0.40 and 0.45, respectively). CONCLUSIONS: S-Detect is a clinically feasible diagnostic tool that can be used to improve the specificity, PPV, and accuracy of breast US, with a moderate degree of agreement in final assessments, regardless of the experience of the radiologist.
Full Text
https://onlinelibrary.wiley.com/doi/abs/10.1002/jum.14332
DOI
10.1002/jum.14332
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Eun-Kyung(김은경) ORCID logo https://orcid.org/0000-0002-3368-5013
Yoon, Jung Hyun(윤정현) ORCID logo https://orcid.org/0000-0002-2100-3513
Cho, Eun(조은)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/161977
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links