0 620

Cited 94 times in

Comparison of shear wave velocities on ultrasound elastography between different machines, transducers, and acquisition depths: a phantom study

DC Field Value Language
dc.contributor.author김명준-
dc.contributor.author신현주-
dc.contributor.author이미정-
dc.contributor.author김하얀-
dc.date.accessioned2017-10-26T07:27:45Z-
dc.date.available2017-10-26T07:27:45Z-
dc.date.issued2016-
dc.identifier.issn0938-7994-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/152062-
dc.description.abstractOBJECTIVES: To investigate consistency in shear wave velocities (SWVs) on ultrasound elastography using different machines, transducers and acquisition depths. METHODS: The SWVs were measured using an elasticity phantom with a Young's modulus of 16.9 kPa, with three recently introduced ultrasound elastography machines (A, B and C from different vendors) and two transducers (low and high frequencies) at four depths (2, 3, 4 and 5 cm). Mean SWVs from 15 measurements and coefficient of variations (CVs) were compared between three machines, two transducers and four acquisition depths. RESULTS: The SWVs using the high frequency transducer were not acquired at 5 cm depth in machine B, and a high frequency transducer was not available in machine C. The mean SWVs in the three machines were different (p?≤?0.002). The CVs were 0-0.09 in three machines. The mean SWVs between the two transducers were different (p?<?0.001) except at 4 and 5 cm depths in machine A. The SWVs were affected by the acquisition depths in all conditions (p?<?0.001). CONCLUSION: There is considerable difference in SWVs on ultrasound elastography depending on different machines, transducers and acquisition depths. Caution is needed when using the cutoff values of SWVs in different conditions. KEY POINTS: ? The shear wave velocities (SWVs) are different between different ultrasound elastography machines ? The SWVs are also different between different transducers and acquisition depths ? Caution is needed when using the cutoff SWVs measured under different conditions.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSpringer International-
dc.relation.isPartOfEUROPEAN RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHElastic Modulus*-
dc.subject.MESHElasticity Imaging Techniques/instrumentation*-
dc.subject.MESHHumans-
dc.subject.MESHPhantoms, Imaging*-
dc.subject.MESHTransducers*-
dc.titleComparison of shear wave velocities on ultrasound elastography between different machines, transducers, and acquisition depths: a phantom study-
dc.typeArticle-
dc.publisher.locationGermany-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Radiology-
dc.contributor.googleauthorHyun Joo Shin-
dc.contributor.googleauthorMyung-Joon Kim-
dc.contributor.googleauthorHa Yan Kim-
dc.contributor.googleauthorYun Ho Roh-
dc.contributor.googleauthorMi-Jung Lee-
dc.identifier.doi10.1007/s00330-016-4212-y-
dc.contributor.localIdA02178-
dc.contributor.localIdA02774-
dc.contributor.localIdA01091-
dc.contributor.localIdA00425-
dc.relation.journalcodeJ00851-
dc.identifier.eissn1432-1084-
dc.identifier.pmid26815368-
dc.identifier.urlhttps://link.springer.com/article/10.1007%2Fs00330-016-4212-y-
dc.subject.keywordComparison-
dc.subject.keywordConsistency-
dc.subject.keywordElastography-
dc.subject.keywordPhantom-
dc.subject.keywordUltrasound-
dc.contributor.alternativeNameKim, Myung Joon-
dc.contributor.alternativeNameShin, Hyun Joo-
dc.contributor.alternativeNameLee, Mi Jung-
dc.contributor.alternativeNameKim, Ha Yan-
dc.contributor.affiliatedAuthorShin, Hyun Joo-
dc.contributor.affiliatedAuthorLee, Mi Jung-
dc.contributor.affiliatedAuthorKim, Ha Yan-
dc.contributor.affiliatedAuthorKim, Myung Joon-
dc.citation.volume26-
dc.citation.number10-
dc.citation.startPage3361-
dc.citation.endPage3367-
dc.identifier.bibliographicCitationEUROPEAN RADIOLOGY, Vol.26(10) : 3361-3367, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid46842-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.