0 435

Cited 0 times in

Manganese Dipyridoxyl Diphosphate (MnDPDP)- Enhanced Magnetic Resonance Imaging of Acute Reperfused Myocardial Injury in a Cat Model: Part II: Comparison With Cine Magnetic Resonance Imaging

Authors
 Dong Hyun Yang  ;  Tae Hoon Kim  ;  Jin Woo Choi  ;  Sang Tae Kim  ;  Jin Ho Yoon  ;  Ji Hoon Shin  ;  Joon Beom Seo  ;  Tae-Hwan Lim 
Citation
 INVESTIGATIVE RADIOLOGY, Vol.40(1) : 56-61, 2005 
Journal Title
INVESTIGATIVE RADIOLOGY
ISSN
 0020-9996 
Issue Date
2005
MeSH
Acute Disease ; Animals ; Cats ; Contrast Media* ; Disease Models, Animal* ; Edetic Acid/analogs & derivatives* ; Magnetic Resonance Imaging/methods* ; Magnetic Resonance Imaging, Cine ; Myocardial Reperfusion Injury/diagnosis* ; Pyridoxal Phosphate/analogs & derivatives*
Keywords
15597021
Abstract
RATIONALE AND OBJECTIVES: To compare manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) with cine MRI for distinguishing the dysfunctional myocardium from the normal myocardium.
MATERIALS AND METHODS: Seventeen cats were prepared for acute myocardial infarction with 90 minutes of occlusion followed by 120 minutes of reperfusion. In vivo inversion-recovery gradient-recalled echo MRI and cine MRI were performed. Two radiologists independently analyzed the MR images and recorded the size of the unenhanced area on the MnDPDP-enhanced MR images as well as that of the dysfunctional area on the cine MR images. Agreement between these abnormal areas was evaluated using Bland-Altman analysis. Interobserver agreement was assessed using Bland-Altman analysis.
RESULTS: The sizes of the unenhanced area on the MnDPDP-enhanced MR images and the dysfunctional area on the cine MR images showed good agreement on Bland-Altman analysis (the limits of agreement: observer 1= 1.8% +/- 11.6, observer 2 = 0.1% +/- 9.9). The abnormal segments on both types of MR imaging showed a good interobserver agreement (the limits of agreement: MnDPDP-enhanced MRI = 0.3% +/- 7.6, cine MRI = -1.4% +/- 10.9).
CONCLUSION: The size of the dysfunctional area on the cine MR images was well correlated with that of the unenhanced area on the MnDPDP-enhanced MR images.
Full Text
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&AN=00004424-200501000-00010&LSLINK=80&D=ovft
DOI
OAK-2005-02507
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Tae Hoon(김태훈) ORCID logo https://orcid.org/0000-0003-3598-2529
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/147334
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links