508 960

Cited 7 times in

Permeability Parameters Measured with Dynamic Contrast-Enhanced MRI: Correlation with the Extravasation of Evans Blue in a Rat Model of Transient Cerebral Ischemia

DC Field Value Language
dc.contributor.author김진아-
dc.contributor.author신나영-
dc.contributor.author안성수-
dc.contributor.author이승구-
dc.contributor.author이종은-
dc.contributor.author이혜연-
dc.contributor.author허지회-
dc.date.accessioned2016-02-04T11:46:36Z-
dc.date.available2016-02-04T11:46:36Z-
dc.date.issued2015-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/141177-
dc.description.abstractOBJECTIVE: The purpose of this study was to correlate permeability parameters measured with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a clinical 3-tesla scanner with extravasation of Evans blue in a rat model with transient cerebral ischemia. MATERIALS AND METHODS: Sprague-Dawley rats (n = 13) with transient middle cerebral artery occlusion were imaged using a 3-tesla MRI with an 8-channel wrist coil. DCE-MRI was performed 12 hours, 18 hours, and 36 hours after reperfusion. Permeability parameters (K(trans), ve, and vp) from DCE-MRI were calculated. Evans blue was injected after DCE-MRI and extravasation of Evans blue was correlated as a reference with the integrity of the blood-brain barrier. Correlation analysis was performed between permeability parameters and the extravasation of Evans blue. RESULTS: All permeability parameters (K(trans), ve, and vp) showed a linear correlation with extravasation of Evans blue. Among them, K(trans) showed highest values of both the correlation coefficient and the coefficient of determination (0.687 and 0.473 respectively, p < 0.001). CONCLUSION: Permeability parameters obtained by DCE-MRI at 3-T are well-correlated with Evans blue extravasation, and K(trans) shows the strongest correlation among the tested parameters.-
dc.description.statementOfResponsibilityopen-
dc.format.extent791~797-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAnimals-
dc.subject.MESHBlood-Brain Barrier/pathology-
dc.subject.MESHCapillary Permeability-
dc.subject.MESHContrast Media-
dc.subject.MESHDisease Models, Animal-
dc.subject.MESHEvans Blue/analysis-
dc.subject.MESHIschemic Attack, Transient/diagnosis*-
dc.subject.MESHMagnetic Resonance Imaging/instrumentation-
dc.subject.MESHMagnetic Resonance Imaging/methods*-
dc.subject.MESHMale-
dc.subject.MESHRats-
dc.subject.MESHRats, Sprague-Dawley-
dc.subject.MESHStroke/diagnosis-
dc.titlePermeability Parameters Measured with Dynamic Contrast-Enhanced MRI: Correlation with the Extravasation of Evans Blue in a Rat Model of Transient Cerebral Ischemia-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anatomy (해부학)-
dc.contributor.googleauthorHyun Seok Choi-
dc.contributor.googleauthorSung Soo Ahn-
dc.contributor.googleauthorNa Young Shin-
dc.contributor.googleauthorJinna Kim-
dc.contributor.googleauthorJae Hyung Kim-
dc.contributor.googleauthorJong Eun Lee-
dc.contributor.googleauthorHye Yeon Lee-
dc.contributor.googleauthorJi Hoe Heo-
dc.contributor.googleauthorSeung Koo Lee-
dc.identifier.doi10.3348/kjr.2015.16.4.791-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02089-
dc.contributor.localIdA02912-
dc.contributor.localIdA04369-
dc.contributor.localIdA03313-
dc.contributor.localIdA03146-
dc.contributor.localIdA02234-
dc.contributor.localIdA01022-
dc.relation.journalcodeJ02884-
dc.identifier.eissn2005-8330-
dc.identifier.pmid26175578-
dc.subject.keywordAnimal models-
dc.subject.keywordBlood-brain barrier-
dc.subject.keywordBrain ischemia-
dc.subject.keywordDynamic contrast-enhanced MRI-
dc.subject.keywordKinetic modeling-
dc.contributor.alternativeNameKim, Jinna-
dc.contributor.alternativeNameShin, Na Young-
dc.contributor.alternativeNameAhn, Sung Soo-
dc.contributor.alternativeNameLee, Seung Koo-
dc.contributor.alternativeNameLee, Jong Eun-
dc.contributor.alternativeNameLee, Hye Yeon-
dc.contributor.alternativeNameHeo, Ji Hoe-
dc.contributor.affiliatedAuthorShin, Na Young-
dc.contributor.affiliatedAuthorLee, Seung Koo-
dc.contributor.affiliatedAuthorHeo, Ji Hoe-
dc.contributor.affiliatedAuthorLee, Hye Yeon-
dc.contributor.affiliatedAuthorLee, Jong Eun-
dc.contributor.affiliatedAuthorAhn, Sung Soo-
dc.contributor.affiliatedAuthorKim, Jinna-
dc.rights.accessRightsfree-
dc.citation.volume16-
dc.citation.number4-
dc.citation.startPage791-
dc.citation.endPage797-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, Vol.16(4) : 791-797, 2015-
dc.identifier.rimsid29345-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anatomy (해부학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Neurology (신경과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.