Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation

Authors
 Jae-Hoon Kim  ;  Byeong-Hoon Cho  ;  Jin-Hee Lee  ;  Soo-Jung Kwon  ;  Young-Ah Yi  ;  Yooseok Shin  ;  Byoung-Duck Roh  ;  Deog-Gyu Seo 
Citation
 ACTA ODONTOLOGICA SCANDINAVICA, Vol.73(2) : 107-113, 2015 
Journal Title
ACTA ODONTOLOGICA SCANDINAVICA
ISSN
 0001-6357 
Issue Date
2015
MeSH
Cementation/methods* ; Ceramics/chemistry* ; Computer-Aided Design ; Crowns*/classification ; Dental Marginal Adaptation* ; Dental Porcelain/chemistry* ; Dental Prosthesis Design* ; Dental Prosthesis Retention ; Humans ; Molar ; Random Allocation ; Resin Cements/chemistry ; Surface Properties ; Tooth Preparation, Prosthodontic/methods ; X-Ray Microtomography
Keywords
CAD/CAM ; internal gap ; luting space ; marginal gap ; micro CT
Abstract
OBJECTIVE: This study investigated the influence of preparation design on the marginal and internal gap and ceramic thickness of partial ceramic crowns (PCCs) fabricated with the CEREC 3 system.

MATERIALS AND METHODS: Sixteen extracted human mandibular molars were prepared according to two different preparation designs (n = 8): a retentive preparation design with traditional cusp capping (Group I) and a non-retentive preparation design with horizontal reduction of cusps (Group II). PCCs were fabricated from IPS Empress CAD with the CEREC 3 system. The parameters for luting space and minimum occlusal ceramic thickness were set to 30 μm and 1.5 mm, respectively. The fabricated PCCs were cemented to their corresponding teeth with self-adhesive resin cement and were then scanned by micro-computed tomography. The marginal and internal gaps were measured at pre-determined measuring points in five bucco-lingual and three mesio-distal cross-sectional images. The ceramic thicknesses of the PCCs were measured at the measuring points for cusp capping areas.

RESULTS: Group II (167.4 ± 76.4 μm) had a smaller overall mean gap, which included the marginal and internal gap measurements, than that of Group I (184.8 ± 89.0 μm). The internal gaps were larger than the marginal gaps, regardless of preparation design. Group I presented a thinner ceramic thickness in the cusp capping areas than the minimum occlusal ceramic thickness parameter of 1.5 mm. CONCLUSION. Preparation design had an influence on fit, particularly the internal gap of the PCCs. Ceramic thickness could be thinner than the minimum ceramic thickness parameter.
Full Text
http://www.tandfonline.com/doi/full/10.3109/00016357.2014.956145#abstract
DOI
10.3109/00016357.2014.956145
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers
Yonsei Authors
Roh, Byoung Duck(노병덕)
Shin, Yoo Seok(신유석) ORCID logo https://orcid.org/0000-0003-1121-2570
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/140232
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links