0 778

Cited 29 times in

Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation

DC Field Value Language
dc.contributor.author노병덕-
dc.contributor.author신유석-
dc.date.accessioned2016-02-04T11:21:07Z-
dc.date.available2016-02-04T11:21:07Z-
dc.date.issued2015-
dc.identifier.issn0001-6357-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/140232-
dc.description.abstractOBJECTIVE: This study investigated the influence of preparation design on the marginal and internal gap and ceramic thickness of partial ceramic crowns (PCCs) fabricated with the CEREC 3 system. MATERIALS AND METHODS: Sixteen extracted human mandibular molars were prepared according to two different preparation designs (n = 8): a retentive preparation design with traditional cusp capping (Group I) and a non-retentive preparation design with horizontal reduction of cusps (Group II). PCCs were fabricated from IPS Empress CAD with the CEREC 3 system. The parameters for luting space and minimum occlusal ceramic thickness were set to 30 μm and 1.5 mm, respectively. The fabricated PCCs were cemented to their corresponding teeth with self-adhesive resin cement and were then scanned by micro-computed tomography. The marginal and internal gaps were measured at pre-determined measuring points in five bucco-lingual and three mesio-distal cross-sectional images. The ceramic thicknesses of the PCCs were measured at the measuring points for cusp capping areas. RESULTS: Group II (167.4 ± 76.4 μm) had a smaller overall mean gap, which included the marginal and internal gap measurements, than that of Group I (184.8 ± 89.0 μm). The internal gaps were larger than the marginal gaps, regardless of preparation design. Group I presented a thinner ceramic thickness in the cusp capping areas than the minimum occlusal ceramic thickness parameter of 1.5 mm. CONCLUSION. Preparation design had an influence on fit, particularly the internal gap of the PCCs. Ceramic thickness could be thinner than the minimum ceramic thickness parameter.-
dc.description.statementOfResponsibilityopen-
dc.format.extent107~113-
dc.relation.isPartOfACTA ODONTOLOGICA SCANDINAVICA-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHCementation/methods*-
dc.subject.MESHCeramics/chemistry*-
dc.subject.MESHComputer-Aided Design-
dc.subject.MESHCrowns*/classification-
dc.subject.MESHDental Marginal Adaptation*-
dc.subject.MESHDental Porcelain/chemistry*-
dc.subject.MESHDental Prosthesis Design*-
dc.subject.MESHDental Prosthesis Retention-
dc.subject.MESHHumans-
dc.subject.MESHMolar-
dc.subject.MESHRandom Allocation-
dc.subject.MESHResin Cements/chemistry-
dc.subject.MESHSurface Properties-
dc.subject.MESHTooth Preparation, Prosthodontic/methods-
dc.subject.MESHX-Ray Microtomography-
dc.titleInfluence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Conservative Dentistry (보존과학)-
dc.contributor.googleauthorJae-Hoon Kim-
dc.contributor.googleauthorByeong-Hoon Cho-
dc.contributor.googleauthorJin-Hee Lee-
dc.contributor.googleauthorSoo-Jung Kwon-
dc.contributor.googleauthorYoung-Ah Yi-
dc.contributor.googleauthorYooseok Shin-
dc.contributor.googleauthorByoung-Duck Roh-
dc.contributor.googleauthorDeog-Gyu Seo-
dc.identifier.doi10.3109/00016357.2014.956145-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01280-
dc.contributor.localIdA02129-
dc.relation.journalcodeJ00023-
dc.identifier.eissn1502-3850-
dc.identifier.pmid25299600-
dc.identifier.urlhttp://www.tandfonline.com/doi/full/10.3109/00016357.2014.956145#abstract-
dc.subject.keywordCAD/CAM-
dc.subject.keywordinternal gap-
dc.subject.keywordluting space-
dc.subject.keywordmarginal gap-
dc.subject.keywordmicro CT-
dc.contributor.alternativeNameRoh, Byoung Duck-
dc.contributor.alternativeNameShin, Yoo Seok-
dc.contributor.affiliatedAuthorRoh, Byoung Duck-
dc.contributor.affiliatedAuthorShin, Yoo Seok-
dc.rights.accessRightsnot free-
dc.citation.volume73-
dc.citation.number2-
dc.citation.startPage107-
dc.citation.endPage113-
dc.identifier.bibliographicCitationACTA ODONTOLOGICA SCANDINAVICA, Vol.73(2) : 107-113, 2015-
dc.identifier.rimsid50366-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.