Efficacy of skull plain films in follow-up evaluation of cerebral aneurysms treated with detachable coils: quantitative assessment of coil mass

Authors
 S.J. Ahn  ;  B.M. Kim  ;  W.S. Jung  ;  S.H. Suh 
Citation
 AMERICAN JOURNAL OF NEURORADIOLOGY, Vol.36(2) : 337-341, 2015 
Journal Title
AMERICAN JOURNAL OF NEURORADIOLOGY
ISSN
 0195-6108 
Issue Date
2015
MeSH
Adult ; Aged ; Area Under Curve ; Cerebral Angiography/instrumentation ; Embolization, Therapeutic/instrumentation* ; Female ; Follow-Up Studies ; Humans ; Intracranial Aneurysm/diagnostic imaging* ; Intracranial Aneurysm/therapy* ; Male ; Middle Aged ; ROC Curve ; Recurrence ; Retrospective Studies ; Sensitivity and Specificity ; Skull/diagnostic imaging*
Abstract
BACKGROUND AND PURPOSE: Skull plain films of coiled aneurysms have been used in a limited role, including morphologic comparison of the coil mass. We aimed to evaluate the efficacy of skull plain films in patients treated with detachable coils by using quantitative assessment.

MATERIALS AND METHODS: In this retrospective study, 78 pairs of the initial and follow-up skull anteroposterior and lateral images were reviewed independently by 2 neuroradiologists. The largest diameter, the perpendicular diameter, and area of the coil mass were measured separately on plain film, and quantitative changes of parameters were compared between subgroups, which were determined by consensus, depending on the need for retreatment. Subgroup analysis was also performed according to aneurysm size, packing attenuation, and ruptured status.

RESULTS: On skull lateral images, mean quantitative changes of the largest diameter (0.53 ± 0.43 mm versus 1.17 ± 0.91 mm, P < .01), the perpendicular diameter (0.56 ± 0.48 mm versus 1.20 ± 1.05 mm, P < .01), and the area of the coil mass (5.21 ± 7.51 mm(2) versus 10.55 ± 10.93 mm(2), P < .02) differed significantly between subgroups. Receiver operating characteristic analysis showed quantitative change of the largest diameter (>1.1 mm; sensitivity, 50.0%; specificity, 90.3%), the perpendicular diameter (>.9 mm; sensitivity, 62.5%; specificity, 85.5%), and the area (>8.5 mm(2); sensitivity, 50.0%; specificity, 83.9%) on skull lateral films to be indicative of aneurysm recurrence, and the diagnostic accuracy of these parameters increased significantly in the high-packing-attenuation group.

CONCLUSIONS: Quantitative measurement of the coil mass by using skull plain lateral images has the potential to predict aneurysm recurrence in follow-up evaluations of intracranial aneurysms with coiling.
Full Text
http://www.ajnr.org/content/36/2/337.long
DOI
10.3174/ajnr.A4121
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Byung Moon(김병문) ORCID logo https://orcid.org/0000-0001-8593-6841
Suh, Sang Hyun(서상현) ORCID logo https://orcid.org/0000-0002-7098-4901
Ahn, Sung Jun(안성준) ORCID logo https://orcid.org/0000-0003-0075-2432
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/139416
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links