436 633

Cited 0 times in

인조혈관스텐트를 이용한 Stanford B형 대동맥 박리증의 치료

Other Titles
 Favorable outcome of endovascular stent-graft implantation for Stanford type B aortic dissection. 
Authors
 강웅철  ;  정보영  ;  심원흠  ;  장병철  ;  이도연  ;  최동훈  ;  구본권  ;  고영국 
Citation
 KOREAN CIRCULATION JOURNAL, Vol.33(6) : 457-464, 2003 
Journal Title
KOREAN CIRCULATION JOURNAL(순환기)
ISSN
 1738-5520 
Issue Date
2003
MeSH
Stent-graft;Aneurysm ; dissecting
Keywords
Stent-graft;Aneurysm ; dissecting
Abstract
Background and Objectives:To evaluate the feasibility and the short- and mid-term follow-up outcomes of endovascular stent-graft implantation in patients with Stanford type B aortic dissection. Subjects and Methods:Twenty-eight patients with Stanford type B aortic dissection were evaluated. An aortogram was performed immediately after the procedure and a follow-up computed tomography (CT) scan was performed within one week, between 3 and 6 months, and annually thereafter. Clinical status was also evaluated at the same time. Results:Endovascular stent-graft implantation at the target site was successful in 27 patients (96.4%). There were primary endoleaks in 6 patients and one case of procedure failure owing to migration of the stent-graft; and no procedure-related mortality. The number of patients with early complications requiring treatment was 2 (2/27, 4%). Fourteen patients experienced postimplantation syndrome (14/27, 52%). The average follow-up period was 22.1±17.5 months. Complete resolution or thrombosis of the false lumen was achieved in 14 patients and partial thrombosis was achieved in 10 patients. Operative treatments were required in three patients due to a progressing dissection or new dissection. There were no deaths and no instances of aneurysm or aortic rupture during the follow-up period. Conclusion:Endovascular stent-graft implantation for Stanford type B aortic dissection is a feasible, safe, and effective treatment modality. All patients who underwent surgery had a persisting leak. Therefore, regular evaluation of the aortic dissection and management of endoleaks were crucial for a favorable outcome in endovascular stent-graft implantation for a Stanford type B aortic dissection.
Files in This Item:
T200305023.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Lee, Do Yun(이도연)
Joung, Bo Young(정보영) ORCID logo https://orcid.org/0000-0001-9036-7225
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/114170
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links