0 509

Cited 32 times in

Position of the superficial femoral artery in closed hip nailing

Authors
 Kyu Hyun Yang  ;  Choon Sik Yoon  ;  Sung Jin Park  ;  Jong Hoon Won  ;  Hui Wan Park 
Citation
 ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, Vol.124(3) : 169-172, 2004 
Journal Title
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY
ISSN
 0936-8051 
Issue Date
2004
MeSH
Adolescent ; Adult ; Aged ; Bone Nails ; Femoral Artery/anatomy & histology* ; Femoral Artery/diagnostic imaging ; Fracture Fixation, Internal/methods* ; Hip Fractures/surgery* ; Humans ; Middle Aged ; Posture ; Ultrasonography, Doppler, Color
Abstract
INTRODUCTION: Adduction of the ipsilateral hip joint is necessary to facilitate closed hip nailing for trochanteric fracture. Even though positioning the patient supine with the perineal post against the ipsilateral medial thigh can change the course of the neurovascular structure in the proximal thigh, there have been no reports regarding the position of the femoral artery in the hip nailing position.
MATERIALS AND METHODS: We studied the position of the superficial femoral artery in 59 thighs using color-flow duplex scanning method in three hip nailing positions.
RESULTS: The mean of the distance between the superficial femoral artery and the femur in 48 normal limbs was 20.28 mm in neutral position (D1), 11.85 mm in 20(o) adduction (D2), and 9.53 mm in 20(o) adduction plus 20(o) internal rotation of the foot plate (D3). The distances D2 and D3 were always shorter than D1 ( p<0.001). D3 was less than 10 mm in 30 of the normal limbs (62.5%) and less than 5 mm in 4 (8%). In 11 patients who sustained a trochanteric fracture, the mean of D1, D2, and D3 in the injured limbs was 25.28 mm, 17.98 mm, and 14.38 mm, respectively. The mid-thigh circumference and D3 of the injured limbs were always greater than those of the normal limbs ( p<0.001). However, D3 of both sides was less than 10 mm in 3 patients.
CONCLUSION: To lessen the vascular injury during hip nailing, we recommend that the limb be placed in neutral position during preparation of the interlocking holes.
Full Text
http://link.springer.com/article/10.1007%2Fs00402-003-0618-5
DOI
10.1007/s00402-003-0618-5
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Park, Hui Wan(박희완)
Yang, Kyu Hyun(양규현) ORCID logo https://orcid.org/0000-0001-7183-588X
Yoon, Choon Sik(윤춘식) ORCID logo https://orcid.org/0000-0003-2010-6710
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/111261
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links