367 567

Cited 16 times in

Feasibility and diagnostic accuracy of whole heart coronary MR angiography using free-breathing 3D balanced turbo-field-echo with SENSE and the half-Fourier acquisition technique

Authors
 Young Jin Kim  ;  Jae-Seung Seo  ;  Byoung Wook Choi  ;  Kyu Ok Choe  ;  Yangsoo Jang  ;  Young-Guk Ko 
Citation
 KOREAN JOURNAL OF RADIOLOGY, Vol.7(4) : 235-242, 2006 
Journal Title
KOREAN JOURNAL OF RADIOLOGY
ISSN
 1229-6929 
Issue Date
2006
MeSH
Adult ; Aged ; Analysis of Variance ; Coronary Angiography ; Coronary Stenosis/diagnosis* ; Feasibility Studies ; Female ; Fourier Analysis ; Humans ; Imaging, Three-Dimensional* ; Magnetic Resonance Angiography/methods* ; Male ; Middle Aged ; Reproducibility of Results
Keywords
Coronary angiography ; Magnetic resonance (MR), angiography
Abstract
Objective: We wanted to assess the feasibility and diagnostic accuracy of whole heart coronary magnetic resonance angiography (MRA) with using 3D balanced turbo-field-echo (b-TFE) with SENSE and the half-Fourier acquisition technique for identifying stenoses of the coronary artery.

Materials and Methods: Twenty-one patients who underwent both whole heart coronary MRA examinations and conventional catheter coronary angiography examinations were enrolled in the study. The whole heart coronary MRA images were acquired using a navigator gated 3D b-TFE sequence with SENSE and the half-Fourier acquisition technique to reduce the acquisition time. The imaging slab covered the whole heart (80 contiguous slices with a reconstructed slice thickness of 1.5 mm) along the transverse axis. The quality of the images was evaluated by using a 5-point scale (0 -uninterpretable, 1 - poor, 2 - fair, 3 - good, 4 - excellent). Ten coronary segments of the heart were evaluated in each case; the left main coronary artery (LM), and the proximal, middle and distal segments of the left anterior descending (LAD), the left circumflex (LCX) and the right coronary artery (RCA). The diagnostic accuracy of whole heart coronary MRA for detecting significant coronary artery stenosis was determined on the segment-by-segment basis, and it was compared with the results obtained by conventional catheter angiography, which is the gold standard.

Results: The mean image quality was 3.7 in the LM, 3.2 in the LAD, 2.5 in the LCX, and 3.3 in the RCA, respectively (the overall image quality was 3.0±0.1). 168 (84%) of the 201 segments had an acceptable image quality (≥grade 2). The sensitivity, specificity, accuracy, negative predictive value and positive predictive value of the whole heart coronary MRA images for detecting significant stenosis were 81.3%, 92.1%, 91.1%, 97.9%, and 52.0%, respectively. The mean coronary MRA acquisition time was 9 min 22 sec (±125 sec).

Conclusion: Whole heart coronary MRA is a feasible technique, and it has good potential to evaluate the major portions of the coronary arteries with an acceptable image quality within a reasonable scan time.
Files in This Item:
T200604541.pdf Download
DOI
10.3348/kjr.2006.7.4.235
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Young Jin(김영진) ORCID logo https://orcid.org/0000-0002-6235-6550
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Choe, Kyu Ok(최규옥)
Choi, Byoung Wook(최병욱) ORCID logo https://orcid.org/0000-0002-8873-5444
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/111011
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links