Titanium and its alloys are widely used in biomedical and dental fields because of their excellent corrosion resistance and biocompatibility. It is well known that titanium is protected from corrosion because of the stability of the passive film that controls and determines the corrosion resistance and biocompatibility of titanium and its alloys. The purpose of this study was to evaluate the electrochemical properties of titanium–silver alloys and the surface characteristics of passive film in artificial saliva.
We designed titanium–silver alloys with silver contents ranging from 0 to 5 at.%, in 1% increments. These alloys were arc-melted, homogenized, hot-rolled to 2 mm thickness, and finally solution heat-treated for 1 h and quenched. Potentiostatic testing was performed, and the open circuit potentials of the alloys were measured in artificial saliva, at 37 °C. The passive films of the titanium–silver alloys were analyzed via XPS.